Coefficient of the Performance of a Segmented Thermoelectric Cooling Leg
- Authors: Drabkin I.A.1
-
Affiliations:
- RMT Ltd.
- Issue: Vol 53, No 5 (2019)
- Pages: 678-681
- Section: XVI International Conference “thermoelectrics and Their Applications–2018” (Iscta 2018,) St. Petersburg, October 8–12, 2018
- URL: https://journals.rcsi.science/1063-7826/article/view/206152
- DOI: https://doi.org/10.1134/S1063782619050051
- ID: 206152
Cite item
Abstract
One of the main energy characteristics of a cooling leg is the maximum available temperature difference (ΔTmax). Its increase indicates an increase in the coefficient of performance (COP) at all temperatures. The use of a segmented leg makes it possible to increase the ΔTmax value; however, the maximum available COP increases only at large temperature differences, whereas at small temperature differences the maximum available COP is even smaller than in a simple leg.
About the authors
I. A. Drabkin
RMT Ltd.
Author for correspondence.
Email: igordrabk@gmail.com
Russian Federation, Moscow, 115230