Comparison of separation performance of polysaccaride-based chiral stationary phases in enantioseparation of 1-(4-chlorobenzhydryl)piperazine benzamide derivatives by HPLC


Cite item

Full Text

Open Access Open Access
Restricted Access Access granted
Restricted Access Subscription Access

Abstract

Analytical high-performance liquid chromatographic enantioseparation of 1-(4-chlorobenzhydryl) piperazine benzamide derivatives was accomplished on different chiral stationary phases. The enantiomers of the compounds were resolved by normal-phase chromatography on silica-based amylose tris(3,5-dimethylphenylcarbamate) (Chiralpak AD-H), cellulose tris(3,5-dimethylphenylcarbamate) (Chiralcel OD-H) and cellulose tris(4-methylbenzoate) (Chiralcel OJ) columns with mobile phases consisting of mixtures of n-hexane and ethanol in different proportions (90: 10, 80: 20). The mobile phase and the chiral stationary phase were varied to achieve the best resolution. The effect of the concentration of ethanol in the mobile phase was studied. The resolution obtained on the three columns was significant.

About the authors

Enise Ece Gurdal

Department of Pharmaceutical Chemistry, Faculty of Pharmacy

Author for correspondence.
Email: egurdal@yeditepe.edu.tr
Turkey, Kayisdagi, Istanbul, 34755

Mine Yarim

Department of Pharmaceutical Chemistry, Faculty of Pharmacy

Email: egurdal@yeditepe.edu.tr
Turkey, Kayisdagi, Istanbul, 34755


Copyright (c) 2017 Pleiades Publishing, Ltd.