Comparison of indicators of autologous serum obtained by different methods and used for the treatment of macular hole
- Authors: Popov E.M.1, Kulikov A.N.1, Churashov S.V.1, Gavrilyuk I.O.1, Egorova E.N.1, Abbasova A.I.1
-
Affiliations:
- S.M. Kirov Medical Military Academy
- Issue: Vol 14, No 4 (2021)
- Pages: 27-34
- Section: Original researches
- URL: https://journals.rcsi.science/ov/article/view/89413
- DOI: https://doi.org/10.17816/OV89413
- ID: 89413
Cite item
Abstract
BACKGROUND: In recent years, autologous serum has been increasingly used in the treatment of macular hole. The study carried out a biological analysis of autologous serum obtained by various methods.
AIM: The aim of the investigation is to compare the cellular and biochemical composition of autologous serum obtained using different methods for use in the macular hole treatment.
MATERIALS AND METHODS: The study of the number of platelets, leukocytes and fibrinogen level in the blood serum of 24 patients obtained by centrifugation in original systems for harvesting autologous serum and laboratory test tubes was performed.
RESULTS: The indices of P-PRP obtained in the Arthrex ACP system and in a laboratory test tube do not statistically differ in quantitative indices of fibrinogen and platelets (p < 0.05), and differ in the content of leukocytes (p > 0.05) in the direction of increasing the number of leukocytes in the substrate obtained in a laboratory test tube. The indicators of L-PRP obtained in the Ycellbio-Kit system and in a laboratory test tube do not statistically differ in the amount of fibrinogen (p < 0.05) and differ in the content of platelets and leukocytes (p > 0.05) in the direction of decreasing the concentration of leukocytes and platelets in the autologous serum obtained in a laboratory test tube.
CONCLUSIONS: Currently, autologous serum obtained in the Arthrex ACP system is of great interest for macular hole surgery due to the minimal content of leukocytes, the closed character of the system, and the best coagulation properties of the substrate obtained. Laboratory test tubes may be considered a more affordable alternative for the production of autologous serum (P-PRP) for the treatment of macular hole. The autologous serum (L-PRP) obtained in the Ycellbio-Kit system and in a laboratory test tube is less suitable for macular hole surgery according to its composition.
Keywords
Full Text
##article.viewOnOriginalSite##About the authors
Evgeniy M. Popov
S.M. Kirov Medical Military Academy
Email: popov138army@mail.ru
ORCID iD: 0000-0002-6606-7027
SPIN-code: 6909-0299
Adjunct of the Department of ophthalmology
Russian Federation, 6, Akademika Lebedeva st., Saint Petersburd, 194044Alexei N. Kulikov
S.M. Kirov Medical Military Academy
Email: alexey.kulikov@mail.ru
ORCID iD: 0000-0002-5274-6993
SPIN-code: 6440-7706
Dr. Sci. (Med.), Associate Professor, Head of the Department of ophthalmology
Russian Federation, 6, Akademika Lebedeva st., Saint Petersburd, 194044Sergey V. Churashov
S.M. Kirov Medical Military Academy
Email: churashoff@mail.ru
ORCID iD: 0000-0003-1197-9237
SPIN-code: 5370-7410
Dr. Sci. (Med.), Professor of the Department of ophthalmology
Russian Federation, 6, Akademika Lebedeva st., Saint Petersburd, 194044Il’ya O. Gavrilyuk
S.M. Kirov Medical Military Academy
Email: gavriluik.vma@gmail.com
ORCID iD: 0000-0003-0932-2818
SPIN-code: 9649-7311
Cand. Sci. (Med.), Lecturer of the Ophthalmology Department
Russian Federation, 6, Akademika Lebedeva st., Saint Petersburd, 194044Elisaveta N. Egorova
S.M. Kirov Medical Military Academy
Email: egorovaelisaveta@mail.ru
ORCID iD: 0000-0002-5272-361X
Cand. Sci. (Med.), Head of the Biochemical Laboratory
Russian Federation, 6, Akademika Lebedeva st., Saint Petersburd, 194044Anastasiya I. Abbasova
S.M. Kirov Medical Military Academy
Author for correspondence.
Email: 3363939@mail.ru
ORCID iD: 0000-0002-6850-4737
Doctor of clinical laboratory diagnostics of the clinical laboratory
Russian Federation, 6, Akademika Lebedeva st., Saint Petersburd, 194044References
- Degenhardt V, Busch C, Jochmann C, et al. Prognostic factors in patients with persistent full-thickness idiopathic macular holes treated with re-vitrectomy with autologous platelet concentrate. Ophthalmologica. 2019;242(4):214–221. doi: 10.1159/000502386
- Shpak AA, Shkvorchenko DO, Krupina EA. Surgical treatment of macular holes with and without the use of autologous platelet-rich plasma. Int Ophthalmol. 2021;41(3):1043–1052. doi: 10.1007/s10792-020-01662-4
- Babu N, Kohli P, Ramachandran NO, et al. Comparison of platelet-rich plasma and inverted internal limiting membrane flap for the management of large macular holes: A pilot study. Indian J Ophthalmol. 2020;68(5):880–884. doi: 10.4103/ijo.IJO_1357_19
- Fayzrahmanov RR, Krupina EA, Pavlovskiy OA, et al. Analysis of platelet-rich plasma obtained in various ways. Medline. ru. Rossiiskii biomeditsinskii zhurnal 2019;20(2):363–372. (In Russ.)
- Shkvorchenko DO, Zakharov VD, Krupina EA, et al. Surgical treatment of primary macular hole using platelet-rich plasma. Fyodorov Journal of Ophthalmic Surgery. 2017;(3):27–30. (In Russ.) doi: 10.25276/0235-4160-2017-3-27-30
- Arsyutov DG. The use of autologous conditioned platelet rich plasma in the surgery of rhegmatogenous retinal detachment with central, paracentral and peripheral tears. Saratov journal of Medical Scientific Research. 2019;15(2):422–425. (In Russ.)
- Kuznetsova NV, Kurenkov VV, Kurenkova NV, Abramov SI. Ispol’zovanie PRP-tekhnologii v konservativnom lechenii diffuznogo lamellyarnogo keratita posle Lasik. Modern technologies in ophthalmology. 2017;(6):183–185. (In Russ.)
- Tarabrina VA, Gavrilyuk IO, Churashov SV, Kulikov AN. The use of platelet-rich plasma on the experimental corneal erosion. Modern technologies in ophthalmology. 2020;(3):83–84. (In Russ.) doi: 10.25276/2312-4911-2020-3-83-84
- Kulikov AN, Churashov SV, Popov EM. Methods of treatment of macular hole: history and prospects. Bulletin of Pirogov National Medical & Surgical Center. 2021;16(1):135–138. (In Russ.) doi: 10.25881/BPNMSC.2021.14.53.026
- Bikbov MM, Zainullin RM, Gilmanshin TR, et al. The results of large macular hole surgery using Autologous conditioned plasma. Point of view. East–West. 2020;(2):33–35. (In Russ.) doi: 10.25276/2410-1257-2020-2-33-35
- Petrachkov DV, Alkharki L, Matyushchenko AG, et al. Comparison of Early Treatment Outcomes for Large Macular Hole Using Various Surgical Techniques. Ophthalmology in Russia. 2021;18(3S):681–687. (In Russ.) doi: 10.18008/1816-5095-2021-3S-681-687
- Shkvorchenko DO, Zakharov VD, Krupina EA, et al. Surgical treatment of primary macular hole using platelet-rich plasma. Fyodorov Journal of Ophthalmic Surgery. 2017;(3):27–30. (In Russ.) doi: 10.25276/0235-4160-2017-3-27-30
- Dohan Ehrenfest DM, Rasmusson L, Albrektsson T. Classification of platelet concentrates: From pure platelet-rich plasma (P-PRP) to leucocyte- and platelet-rich fibrin (L-PRF). Trends Biotechnol. 2009;27(3):158–167. doi: 10.1016/j.tibtech.2008.11.009
- Arthrex.com [Internet]. Instruktsiya po primeneniyu sistemy Arthrex ACP shprits v shpritse firmy Arthrex [cited: 2021 Nov 23]. Available from: https://www.arthrex.com/resources/brochures/pF8_4Jzo7U2V9AF47os7pg/arthrex-acp-double-syringe-hettich-centrifuge (In Russ.)
- PRPLab [Internet]. Instruktsiya po primeneniyu sistemy Ycellbio-Kit firmy Vaisellbiomedikal [cited: 2021 Nov 23]. Available from: http://www.prplab.ru/metod-prp.htm (In Russ.)
- Dolgov VV, Men’shikov VV. Klinicheskaya laboratornaya diagnostika: natsional’noe rukovodstvo, Vol. 1. Moscow: GEHOTAR-Media, 2012. 928 p. (In Russ.)
- Arsyutov DG. The use of a new type of platelet-rich plasma — autologous conditioned plasma (ACP) in the surgery of rhegmatogenous retinal detachment with large and multiple breaks, abruption from the dentate line. Modern technologies in ophthalmology. 2019;(1):22–25. (In Russ.) doi: 10.25276/2312-4911-2019-1-22-25
- Zakharov VD, Shkvorchenko DO, Krupina EA, et al. Efficacy of platelet-rich plasma in surgery of large macular raptures. Practical medicine. 2016;(9):118–121. (In Russ.)
- Fedoseeva EV, Chentsova EV, Borovkova NV, et al. Morphofunctional Peculiarities of Platelet Rich Plasma and Its Application in Ophthalmology. Ophthalmology in Russia. 2018;15(4):388–393. (In Russ.) doi: 10.18008/1816-5095-2018-4-388-393
- Krupina EA, Fajzrahmanov RR, Pavlovskij OA, et al. Molecular and biological аspects of platelet-rich plasma therapies. Bulletin of Pirogov National Medical & Surgical Center. 2020;15(3–2):80–85. (In Russ.) doi: 10.25881/BPNMSC.2020.30.34.015