Study on dependence of phacoemulsification of senile cataract parameters on features of hydrodissection

Cover Page

Cite item

Full Text

Open Access Open Access
Restricted Access Access granted
Restricted Access Subscription Access

Abstract

The aim was to study the dependence of senile cataract phacoemulsification (PE) parameters on hydrodissection (HD) features.

Materials and methods. 64 patients (64 eyes) who underwent PE of senile cataract using either viscodissection (VD) (main group) or regular HD (control group). Time parameters — VD and HD duration, cortex aspiration, and total time of PE, — along with calculation of mean volume of BSS in both groups were studied.

Results. It took 1.8 times more time to perform VD compared to HD duration. The cortex aspiration step required 2.4 times less time in the eyes of main group in comparison with control group, as 10 eyes (31.2%) of the main group had spontaneous full cortex evacuation through ultrasound tip at epinucleus removal. Other 22 eyes (78.8%) of the main group needed aspiration of cortex, which occupied 1/6–1/3 capsule circumference. Though surgery time was comparable in both groups, mean volume of BSS spent was justifiably 1.5 times higher in the control group.

Conclusion. Performed analysis showed that VD is an effective method which provides optimization of PE of senile cataract. Use of VD allowed exclusion of cortex aspiration in 31.2% of eyes in the main group and decrease of its duration by 2.4 times in comparison with the control group.

About the authors

Anna V. Egorova

S. Fyodorov Eye Microsurgery Federal State Institution, the Khabarovsk Branch

Author for correspondence.
Email: naukakhvmntk@mail.ru
ORCID iD: 0000-0002-7079-8359
SPIN-code: 7161-7481
Scopus Author ID: 25631622800

PhD, MD of Highest Qualification, Cataract Surgery Department. S. Fyodorov Eye Microsurgery Federal State Institution, Khabarovsk branch

Russian Federation, 211, Tikhookeanskaya str., Khabarovsk, Russian Federation, 680033

Alexey V. Vasiliev

S. Fyodorov Eye Microsurgery Federal State Institution, the Khabarovsk Branch

Email: naukakhvmntk@mail.ru
ORCID iD: 0000-0001-9712-0276
SPIN-code: 5780-0798

PhD, Chief of Cataract Surgery Department, MD of Highest Qualification. S. Fyodorov Eye Microsurgery Federal State Institution

Russian Federation, 211, Tikhookeanskaya str., Khabarovsk, Russian Federation, 680033

References

  1. Малюгин Б.Э. Хирургия катаракты и интраокулярная коррекция на современном этапе развития офтальмохирургии // Вестник офтальмологии. – 2014. – Т. 130. – № 6. – С. 80–88. [Maliugin BE. State-of-the-art cataract surgery and intraocular optical correction. Russian Annals of Ophthalmology. 2014;130(6):80-88. (In Russ.)]
  2. Шухаев С.В., Ельцина О.М., Балашевич Л.И. Метод сравнительной оценки ультразвуковых и гидродинамических показателей в процессе факоэмульсификации // Вестник офтальмологии. – 2018. – Т. 134 — № 6. – С. 33–40. [Shukhaev SV, Yeltsina OB, Balashevich LI. Comparison of ultrasound and hydrodynamic parameters in phacoemulsification. Russian Annals of Ophthalmology. 2018;134(6):33-40. (In Russ.)] https://doi.org/10.17116/oftalma201813406133
  3. Щуко А.Г., Шантурова М.А., Сенченко Н.Я. и др. Путь к успеху. Этапы развития факоэмульсификации в России // Современные технологии в офтальмологии. – 2017. – № 3. – С. 21–25. [Shchuko AG, Shanturova MA, Senchenko Nya, et al. Put’ k uspekhu. Etapy razvitiya fakoemul’sifikatsii v Rossii. Modern technologies in ophthalmology. 2017;(3):21-25. (In Russ.)]
  4. Vasumathi R. Remembering Dr. Charles D. Kelman and development of phacoemulsification. TNOA J Ophthalmic Sci Res. 2018;56(1):45-50. https://doi.org/10.4103/tjosr.tjosr_36_18
  5. Анисимова С.Ю., Анисимова Н.С., Авсинеева К.М. и др. Клинический анализ осложнений факоэмульсификации с фемтолазерным сопровождением и особенности проведения факоэмульсификации после фемтоэтапа // Офтальмохирургия. – 2014. – № 4. – С. 14–20. [Anisimova SY, Anisimova NS, Avsineeva KM, et al. Clinical analysis of complications and special features of femtosecond laser-assisted cataract surgery. Ophthalmosurgery. 2014;(4):14-20. (In Russ.)]
  6. Бикбов М.М., Бурханов Ю.К., Оренбуркина О.И. и др. Применение фемтолазер-ассистированной ультразвуковой факоэмульсификации при плотных катарактах // Современные технологии в офтальмологии. – 2017. – № 7. – С. 15–18. [Bikbov MM, Burkhanov YuK, Orenburkina OI, et al. Primeneniye femtolazer-assistirovannoy ul’trazvukovoy fakoemul’sifikatsii pri plotnykh kataraktakh. Modern technologies in ophthalmology. 2017;(7):15-18. (In Russ.)]
  7. Подыниногина В.В., Чупров А.Д., Николаев А.А. Оптимизация факоэмульсификации на основе метода многофакторного анализа // Сибирское медицинское обозрение. – 2006. – № 5. – С. 27–28. [Podyninogina VV, Chuprov AD, Nikolaev AA. The optimization of the phacoemulsification on basis of multifactor analysis method. Siberian Medical Review. 2006;(5):27-28. (In Russ.)]
  8. Романенко С.Я., Терещенко А.В., Трифаненкова И.Г. и др. Энергетические параметры фемтолазерного сопровождения хирургии катаракты при различной степени плотности ядра хрусталика // Практическая медицина. – 2016. – № 6. – С. 145–148. [Romanenko SYa, Tereshchenko IG, Trifanenkova VB, et al. Energy parameters of femtosecond laser cataract surgery support at different degrees of the lens nucleus density. Practical medicine. 2016;(6):145-148. (In Russ.)]
  9. Шухаев С.В., Литвин И.Б., Березин С.В. Использование торсионного ультразвука в комбинации с продольным для аспирации плотных катаракт // Глаукома теория и практика. Горизонты нейропротекции: Сборник научных статей VIII научной конференции. – СПб., 2015. – Вып. 10. – С. 92–94. [Shukhayev SV, Litvin IB, Berezin SV. Ispol’zovaniye torsionnogo ul’trazvuka v kombinatsii s prodol’nym dlya aspiratsii plotnykh katarakt. Glaukoma teoriya i praktika. Gorizonty neyroprotektsii: Sbornik nauchnykh statey VIII nauchnoy konferentsii (Conference proceedings). Saint Petersburg: 2015;(10):92-94. (In Russ.)]
  10. Boulter T, Christensen MD, Jensen JD. et al. Optimization and comparison of a 0.7 mm tip with the 0.9 mm tip on an active-fluidics phacoemulsification platform. Journal of Cataract and Refractive Surgery. 2017;43(12):1591-1595. https://doi.org/10.1016/j.jcrs.2017.08.022
  11. Иошин И.Э. Факоэмульсификация: руководство. – М.: 2012. – 104 с. [Ioshin IE. Fakoemul’sifikatsiya: rukovodstvo. Moscow; 2012. 104 p. (In Russ.)]
  12. Кашперская Д.В., Князева Е.С., Коротких С.А. Интраоперационные осложнения при факоэмульсификации катаракты: факторы риска, частота, прогноз // Отражение. – 2018. – № 1(6). – С. 115–118. [Kashperskaia DV, Knyazeva ES, Korotkih SA. Intraoperative complications of phacoemulsification: risk factors, incidence, prediction. Reflection. 2018;(1):115-118. (In Russ.)]
  13. Тен С.С. Сравнительная характеристика вискоэластиков при факоэмульсификации катаракты // Медицина и экология. – 2011. – № 3. – С. 37–39. [Ten SS. Comparative characteristics of viscoelastics at cataract phacoemulsification. Medicine and ecology. 2011;(3):37-39. (In Russ.)]
  14. Vasavada V, Vasavada V, Werner L, et al. Corticocapsular cleavage during phacoemulsification: Viscodissection versus hydrodissection. Miyake-Apple view analysis. J Cataract Refract Sur. 2008;34(7):1173-1180. https://doi.org/10.1016/ j.jcrs.2008.03.026
  15. Cetinkaya S, Cetinkaya YF, Dadaci Z, Acir NO. Phacoemulsification in posterior polar cataract. Arq Bras Oftalmol. 2016;79(4):218-221. https://doi.org/10.5935/0004-2749.20160063
  16. Taskapili M, Gulkilik G, Kocabora MS, Ozsutcu M. Phacoemulsification with viscodissection in posterior polar cataract: minimizing risk of posterior capsule tear. Annals of Ophthalmology. 2007;39(2):145-149. https://doi.org/10.1007/s12009-007-0004-y
  17. Burratto L. Phacoemulsification: Principles and Techniques. Slack Incorporated; 1997. 544 p.

Supplementary files

Supplementary Files
Action
1. JATS XML

Copyright (c) 2020 Egorova A.V., Vasiliev A.V.

Creative Commons License
This work is licensed under a Creative Commons Attribution 4.0 International License.
 


Согласие на обработку персональных данных с помощью сервиса «Яндекс.Метрика»

1. Я (далее – «Пользователь» или «Субъект персональных данных»), осуществляя использование сайта https://journals.rcsi.science/ (далее – «Сайт»), подтверждая свою полную дееспособность даю согласие на обработку персональных данных с использованием средств автоматизации Оператору - федеральному государственному бюджетному учреждению «Российский центр научной информации» (РЦНИ), далее – «Оператор», расположенному по адресу: 119991, г. Москва, Ленинский просп., д.32А, со следующими условиями.

2. Категории обрабатываемых данных: файлы «cookies» (куки-файлы). Файлы «cookie» – это небольшой текстовый файл, который веб-сервер может хранить в браузере Пользователя. Данные файлы веб-сервер загружает на устройство Пользователя при посещении им Сайта. При каждом следующем посещении Пользователем Сайта «cookie» файлы отправляются на Сайт Оператора. Данные файлы позволяют Сайту распознавать устройство Пользователя. Содержимое такого файла может как относиться, так и не относиться к персональным данным, в зависимости от того, содержит ли такой файл персональные данные или содержит обезличенные технические данные.

3. Цель обработки персональных данных: анализ пользовательской активности с помощью сервиса «Яндекс.Метрика».

4. Категории субъектов персональных данных: все Пользователи Сайта, которые дали согласие на обработку файлов «cookie».

5. Способы обработки: сбор, запись, систематизация, накопление, хранение, уточнение (обновление, изменение), извлечение, использование, передача (доступ, предоставление), блокирование, удаление, уничтожение персональных данных.

6. Срок обработки и хранения: до получения от Субъекта персональных данных требования о прекращении обработки/отзыва согласия.

7. Способ отзыва: заявление об отзыве в письменном виде путём его направления на адрес электронной почты Оператора: info@rcsi.science или путем письменного обращения по юридическому адресу: 119991, г. Москва, Ленинский просп., д.32А

8. Субъект персональных данных вправе запретить своему оборудованию прием этих данных или ограничить прием этих данных. При отказе от получения таких данных или при ограничении приема данных некоторые функции Сайта могут работать некорректно. Субъект персональных данных обязуется сам настроить свое оборудование таким способом, чтобы оно обеспечивало адекватный его желаниям режим работы и уровень защиты данных файлов «cookie», Оператор не предоставляет технологических и правовых консультаций на темы подобного характера.

9. Порядок уничтожения персональных данных при достижении цели их обработки или при наступлении иных законных оснований определяется Оператором в соответствии с законодательством Российской Федерации.

10. Я согласен/согласна квалифицировать в качестве своей простой электронной подписи под настоящим Согласием и под Политикой обработки персональных данных выполнение мною следующего действия на сайте: https://journals.rcsi.science/ нажатие мною на интерфейсе с текстом: «Сайт использует сервис «Яндекс.Метрика» (который использует файлы «cookie») на элемент с текстом «Принять и продолжить».