The paper shows the influence of various laser processing modes of cold spray Ni–Ti–WC coatings. It has been shown that the microhardness of the resulting coatings reaches 1200 HV. The formation of diamond-shaped, pore-free WC inclusions with a size of 500 nm has a positive effect on the microhardness. The article provides recommendations for the industrial production of Ni–Ti–WC system coatings.

About the authors

A. M. Makarov

Research Institute "Crystal"

Author for correspondence.
Email: mail@crystal.ru
Cand Sc. (Eng) Petrovskaya St., 49, St. Petersburg, Russia

D. A. Gerashchenkov

Research Institute "Crystal"

Email: mail@crystal.ru
Dr Sc (Eng) Petrovskaya St., 49, St. Petersburg, Russia

R. Yu. Bystrov

Research Institute "Crystal"

Email: mail@crystal.ru
Petrovskaya St., 49, St. Petersburg, Russia

E. A. Popova

Research Institute "Crystal"

Email: mail@crystal.ru
Petrovskaya St., 49, St. Petersburg, Russia

V. V. Bobyr

Research Institute "Crystal"

Email: mail@crystal.ru
Petrovskaya St., 49, St. Petersburg, Russia

A. A. Kashirina

Research Institute "Crystal"

Email: mail@crystal.ru
Petrovskaya St., 49, St. Petersburg, Russia

N. V. Yakovleva

Research Institute "Crystal"

Email: mail@crystal.ru
Petrovskaya St., 49, St. Petersburg, Russia

References

Supplementary files

Supplementary Files
Action
1. JATS XML

Согласие на обработку персональных данных

 

Используя сайт https://journals.rcsi.science, я (далее – «Пользователь» или «Субъект персональных данных») даю согласие на обработку персональных данных на этом сайте (текст Согласия) и на обработку персональных данных с помощью сервиса «Яндекс.Метрика» (текст Согласия).