The comparison of the results of ophthalmometry performed using the Icare tonometer, transpalpebral tonometer TVGD-01, pneumotonometry and Maklakov tonometer in healthy children and patients with congenital glaucoma. We examined 20 children (40 eyes) with compensated congenital glaucoma at the age of 5-17 years, the control group consisted of 43 patients (86 eyes) - healthy children and children with mild myopia. The cornea radius of curvature in children with congenital glaucoma was 8,24±0,08 mm, in healthy children - of 7,68±0,03 mm Hg. Central corneal thickness in 52,5% of patients was 599,20±8,07 pm, 47,5% of patients had 508,90±7,28 pm, while children in the control group had 562,46±4,00 pm. The average intraocular pressure (Po), obtained by tonometry using Icare was 15,3±1,04 mm Hg in children with congenital glaucoma, 18,26±0,46 mm Hg in children of the control group, pneumotonometry was 16,23±2,07 mm Hg and 17,48±0,34 mm Hg respectively. Indicators transpalpebral tonometry (PT) in children with congenital glaucoma - 16,90±0,50 mm Hg, children in the control group - 18,60±0,48 mm Hg, Maklakov tonometry - 18,14±0,58 mm Hg and 18,98±0,24 mm Hg respectively. Positive direct correlation between Icare tonometry and corneal curvature radius (r=0,79) and between central corneal thickness and IOP on Maklakov (r=0,93). A negative correlation between the value of the anteroposterior size of the eye and results transpalpebral tonometry (r=-0,47). Interpretation of intraocular pressure measurementresultsin children with congenital glaucoma should be based on the modified properties of the cornea in these patients.

作者简介

Elina Tugeeva

Saint-Petersburg State Pediatric Medical University

Email: etugeeva@yandex.ru
194100, Saint-Petersburg, Russia

Tat’yana Vorontsova

North-Western State Medical University named after I.I. Mechnikov

195112, Saint-Petersburg, Russia

V. Brzheskiy

Saint-Petersburg State Pediatric Medical University

194100, Saint-Petersburg, Russia

M. Zaytseva

Diagnostic Center №7 (ophthalmological) for adults and children

191028, Saint-Petersburg, Russia

参考

  1. Алексеев В.В. Оценка влияния параметров роговой оболочки на результаты тонометрии в здоровой популяции. Русский медицинский журнал. 2008; 4: 24-7.
  2. Маложен С.А., Белоусова Е.В. Сравнительная оценка тонометров при определении ВГД у пациентов с патологическими изменениями роговицы. Глаукома. 2010; 4: 25-8.
  3. Романенко И.А., Куроедов А.В., Смирнова Т.Б. и др. Взаимоотношение центральной толщины роговицы и методик исследования уровня ВГД. В кн.: Сборник научных статей VII Международной конференции « Глаукома: теории, тенденции, технологии». М.; 2009: 513-9.
  4. Muir K.W., Jin J., Freedman S.F. Central corneal thickness and its relationship to intraocular pressure in children. Ophthalmology. 2004; 111: 2220-3.
  5. Воронцова Т.Н., Тугеева Э.Э., Болотникова И.В., Михайлова М.В. О некоторых анатомо-структурных особенностях роговицы у детей с врожденной глаукомой (предварительное сообщение). В кн.: Материалы научной конференции офтальмологов «Невские горизонты - 2012». Санкт-Петербург; 2012: 70-3.
  6. Сидоренко Е.И., Бондарь Н.О. Проблемы тонометрии в неонатальной офтальмологии. Российская педиатрическая офтальмология. 2009; 2: 46-9.
  7. Сидоров Э.Г., Мирзаянц М.Г. Врожденная глаукома и ее лечение. М.: Медицина; 1991.
  8. Amini H., Fakhraie G., Abolmaali S. et al. Central corneal thickness in Iranian congenitial glaucoma patients. Middle East Afr. J. Ophthalmol. 2012; 19: 194-8.