Droplet-Laden Mist Film Cooling Effectiveness of Cylindrical Holes Embedded in a Transverse Trench
- Авторлар: Pakhomov M.A.1, Terekhov V.I.1
-
Мекемелер:
- Kutateladze Institute of Thermophysics, Siberian Branch
- Шығарылым: Том 27, № 4 (2018)
- Беттер: 387-398
- Бөлім: Article
- URL: https://journals.rcsi.science/1810-2328/article/view/211750
- DOI: https://doi.org/10.1134/S1810232818040021
- ID: 211750
Дәйексөз келтіру
Аннотация
A three-dimensional numerical model of calculating in the Euler approach is developed to calculate a two-phase turbulent near-wall flow; simulation of thermal efficiency of a gas-droplet shielding injected into a transverse trench through inclined cylindrical holes is fulfilled. The influence of the main thermo-gas-dynamic characteristics of the two-phase flow on thermal efficiency is analyzed. Significant increase in thermal efficiency was obtained by adding droplets in the nearwall coolant flow (up to 2 times in comparison with a single-phase flow). A particular advantage of this method of coolant injection is achieved at high injection parameters. It is shown that the use of two-phase gas-droplet near-wall shielding is promising for protection of surfaces against thermal influence of the heated gas flows.
Авторлар туралы
M. Pakhomov
Kutateladze Institute of Thermophysics, Siberian Branch
Хат алмасуға жауапты Автор.
Email: pakhomov@ngs.ru
Ресей, pr. Akad. Lavrent’eva 1, Novosibirsk, 630090
V. Terekhov
Kutateladze Institute of Thermophysics, Siberian Branch
Email: pakhomov@ngs.ru
Ресей, pr. Akad. Lavrent’eva 1, Novosibirsk, 630090
Қосымша файлдар
