Droplet-Laden Mist Film Cooling Effectiveness of Cylindrical Holes Embedded in a Transverse Trench
- Авторы: Pakhomov M.A.1, Terekhov V.I.1
-
Учреждения:
- Kutateladze Institute of Thermophysics, Siberian Branch
- Выпуск: Том 27, № 4 (2018)
- Страницы: 387-398
- Раздел: Article
- URL: https://journals.rcsi.science/1810-2328/article/view/211750
- DOI: https://doi.org/10.1134/S1810232818040021
- ID: 211750
Цитировать
Аннотация
A three-dimensional numerical model of calculating in the Euler approach is developed to calculate a two-phase turbulent near-wall flow; simulation of thermal efficiency of a gas-droplet shielding injected into a transverse trench through inclined cylindrical holes is fulfilled. The influence of the main thermo-gas-dynamic characteristics of the two-phase flow on thermal efficiency is analyzed. Significant increase in thermal efficiency was obtained by adding droplets in the nearwall coolant flow (up to 2 times in comparison with a single-phase flow). A particular advantage of this method of coolant injection is achieved at high injection parameters. It is shown that the use of two-phase gas-droplet near-wall shielding is promising for protection of surfaces against thermal influence of the heated gas flows.
Об авторах
M. Pakhomov
Kutateladze Institute of Thermophysics, Siberian Branch
Автор, ответственный за переписку.
Email: pakhomov@ngs.ru
Россия, pr. Akad. Lavrent’eva 1, Novosibirsk, 630090
V. Terekhov
Kutateladze Institute of Thermophysics, Siberian Branch
Email: pakhomov@ngs.ru
Россия, pr. Akad. Lavrent’eva 1, Novosibirsk, 630090
Дополнительные файлы