Droplet-Laden Mist Film Cooling Effectiveness of Cylindrical Holes Embedded in a Transverse Trench


Citar

Texto integral

Acesso aberto Acesso aberto
Acesso é fechado Acesso está concedido
Acesso é fechado Somente assinantes

Resumo

A three-dimensional numerical model of calculating in the Euler approach is developed to calculate a two-phase turbulent near-wall flow; simulation of thermal efficiency of a gas-droplet shielding injected into a transverse trench through inclined cylindrical holes is fulfilled. The influence of the main thermo-gas-dynamic characteristics of the two-phase flow on thermal efficiency is analyzed. Significant increase in thermal efficiency was obtained by adding droplets in the nearwall coolant flow (up to 2 times in comparison with a single-phase flow). A particular advantage of this method of coolant injection is achieved at high injection parameters. It is shown that the use of two-phase gas-droplet near-wall shielding is promising for protection of surfaces against thermal influence of the heated gas flows.

Sobre autores

M. Pakhomov

Kutateladze Institute of Thermophysics, Siberian Branch

Autor responsável pela correspondência
Email: pakhomov@ngs.ru
Rússia, pr. Akad. Lavrent’eva 1, Novosibirsk, 630090

V. Terekhov

Kutateladze Institute of Thermophysics, Siberian Branch

Email: pakhomov@ngs.ru
Rússia, pr. Akad. Lavrent’eva 1, Novosibirsk, 630090

Arquivos suplementares

Arquivos suplementares
Ação
1. JATS XML

Declaração de direitos autorais © Pleiades Publishing, Ltd., 2018