A high-temperature mass-spectrometric method for determination of the electron work function of ionic crystals: Lanthanum, cerium, and praseodymium triiodides

Full Text

Open Access Open Access
Restricted Access Access granted
Restricted Access Subscription Access

Abstract

A mass spectrometric method for the determination of the electron work function based on analysis of thermochemical cycles including molecules and ions has been described. Application of this method for calculation of the electron work functions of lanthanum, cerium, and praseodymium triiodides gave 3.8±0.3 eV for LaI3, 3.5±0.3 eV for CeI3, and 2.8±0.3 eV for PrI3.

About the authors

A. M. Dunaev

Ivanovo State University of Chemistry and Technology (ISUCT)

Author for correspondence.
Email: amdunaev@ro.ru
Russian Federation, pr. Sheremetevskii 7, Ivanovo, 153000

V. B. Motalov

Ivanovo State University of Chemistry and Technology (ISUCT)

Email: amdunaev@ro.ru
Russian Federation, pr. Sheremetevskii 7, Ivanovo, 153000

L. S. Kudin

Ivanovo State University of Chemistry and Technology (ISUCT)

Email: amdunaev@ro.ru
Russian Federation, pr. Sheremetevskii 7, Ivanovo, 153000


Copyright (c) 2017 Pleiades Publishing, Ltd.