A Low-Frequency Electromagnetic Radiation Analyzer to Determine the Risk-Contributing Factors of an Electromagnetic Situation
- Autores: Titov E.V.1, Soshnikov A.A.1, Drobyazko O.N.1
-
Afiliações:
- Polzunov Altai State Technical University
- Edição: Volume 89, Nº 12 (2018)
- Páginas: 714-716
- Seção: Article
- URL: https://journals.rcsi.science/1068-3712/article/view/231497
- DOI: https://doi.org/10.3103/S1068371218120106
- ID: 231497
Citar
Resumo
To determine the efficiency of shielding from nonionizing electromagnetic radiations, a device that allows one to study electromagnetic fields at separate frequencies with a high sensitivity and to represent the results of measurements as spectral distributions using computer facility has been suggested. The results of measurements of the electromagnetic field from a radiation source shield by different materials have been considered in a limited frequency range. A version of the spectral distribution of an electromagnetic signal has been presented. The dependences of shielding coefficients on the distance between an electromagnetic radiation source and a measuring unit have been plotted for different shielding materials and frequency ranges. The possibility of using the developed device as an analyzer of low-frequency electromagnetic signals both under the steady-state conditions and in domestic service and industrial facilities with a nonaggressive environment has been shown.
Sobre autores
E. Titov
Polzunov Altai State Technical University
Autor responsável pela correspondência
Email: journal-elektrotechnika@mail.ru
Rússia, Barnaul, Altai krai, 656038
A. Soshnikov
Polzunov Altai State Technical University
Email: journal-elektrotechnika@mail.ru
Rússia, Barnaul, Altai krai, 656038
O. Drobyazko
Polzunov Altai State Technical University
Email: journal-elektrotechnika@mail.ru
Rússia, Barnaul, Altai krai, 656038
Arquivos suplementares