Emergency operation processes in the thyristor rectifier of an alernating current electric locomotive


Cite item

Full Text

Open Access Open Access
Restricted Access Access granted
Restricted Access Subscription Access

Abstract

In an electric locomotive, the failure of any element or unit of the control system does not have to cause damage to power circuits or emergency operation. A control strategy for a four-zone ac–dc power converter with a discharge diode branch, which is connected in parallel to the rectified current circuit, is proposed. Such control improves the switching conditions of thyristors and allows reduction in the switching time and a decrease in the equivalent inductive reactance of the ac circuit; in addition, it provides reservation due to simultaneous switching of paralleled thyristor branches and skipping of control pulses in any control zone.

About the authors

S. V. Vlas’evskii

Far Eastern State Transport University

Author for correspondence.
Email: journal-elektrotechnika@mail.ru
Russian Federation, Khabarovsk

O. V. Mel’nichenko

Far Eastern State Transport University

Email: journal-elektrotechnika@mail.ru
Russian Federation, Khabarovsk

O. A. Malysheva

Irkutsk Transport State University

Email: journal-elektrotechnika@mail.ru
Russian Federation, Irkutsk

Supplementary files

Supplementary Files
Action
1. JATS XML

Copyright (c) 2016 Allerton Press, Inc.