Distribution of leakage currents in the cylindrical and conical sections of the magnetically insulated transmission line of the Angara-5-1 facility in experiments with wire arrays
- Autores: Grabovski E.V.1, Gribov A.N.1, Samokhin A.A.1, Shishlov A.O.1
-
Afiliações:
- Troitsk Institute for Innovation and Fusion Research
- Edição: Volume 42, Nº 8 (2016)
- Páginas: 773-778
- Seção: Plasma Diagnostics
- URL: https://journals.rcsi.science/1063-780X/article/view/185887
- DOI: https://doi.org/10.1134/S1063780X16080043
- ID: 185887
Citar
Resumo
Current leakages in the magnetically insulated transmission lines (MITL) impose restrictions on the transmission of electromagnetic pulses to the load in high-power electrophysical facilities. The multimodule Angara-5-1 facility with an output electric power of up to 6 TW is considered. In this work, the experimental and calculated profiles of leakage currents in two sections of the line are compared when the eight-module facility is loaded by a wire array. The azimuthal distribution of the current in the cylindrical section of the MITL is also considered.
Sobre autores
E. Grabovski
Troitsk Institute for Innovation and Fusion Research
Email: Shishlov@triniti.ru
Rússia, Troitsk, Moscow, 142190
A. Gribov
Troitsk Institute for Innovation and Fusion Research
Email: Shishlov@triniti.ru
Rússia, Troitsk, Moscow, 142190
A. Samokhin
Troitsk Institute for Innovation and Fusion Research
Email: Shishlov@triniti.ru
Rússia, Troitsk, Moscow, 142190
A. Shishlov
Troitsk Institute for Innovation and Fusion Research
Autor responsável pela correspondência
Email: Shishlov@triniti.ru
Rússia, Troitsk, Moscow, 142190
Arquivos suplementares
