Distribution of leakage currents in the cylindrical and conical sections of the magnetically insulated transmission line of the Angara-5-1 facility in experiments with wire arrays
- Authors: Grabovski E.V.1, Gribov A.N.1, Samokhin A.A.1, Shishlov A.O.1
-
Affiliations:
- Troitsk Institute for Innovation and Fusion Research
- Issue: Vol 42, No 8 (2016)
- Pages: 773-778
- Section: Plasma Diagnostics
- URL: https://journals.rcsi.science/1063-780X/article/view/185887
- DOI: https://doi.org/10.1134/S1063780X16080043
- ID: 185887
Cite item
Abstract
Current leakages in the magnetically insulated transmission lines (MITL) impose restrictions on the transmission of electromagnetic pulses to the load in high-power electrophysical facilities. The multimodule Angara-5-1 facility with an output electric power of up to 6 TW is considered. In this work, the experimental and calculated profiles of leakage currents in two sections of the line are compared when the eight-module facility is loaded by a wire array. The azimuthal distribution of the current in the cylindrical section of the MITL is also considered.
About the authors
E. V. Grabovski
Troitsk Institute for Innovation and Fusion Research
Email: Shishlov@triniti.ru
Russian Federation, Troitsk, Moscow, 142190
A. N. Gribov
Troitsk Institute for Innovation and Fusion Research
Email: Shishlov@triniti.ru
Russian Federation, Troitsk, Moscow, 142190
A. A. Samokhin
Troitsk Institute for Innovation and Fusion Research
Email: Shishlov@triniti.ru
Russian Federation, Troitsk, Moscow, 142190
A. O. Shishlov
Troitsk Institute for Innovation and Fusion Research
Author for correspondence.
Email: Shishlov@triniti.ru
Russian Federation, Troitsk, Moscow, 142190
Supplementary files