Distribution of leakage currents in the cylindrical and conical sections of the magnetically insulated transmission line of the Angara-5-1 facility in experiments with wire arrays


如何引用文章

全文:

开放存取 开放存取
受限制的访问 ##reader.subscriptionAccessGranted##
受限制的访问 订阅存取

详细

Current leakages in the magnetically insulated transmission lines (MITL) impose restrictions on the transmission of electromagnetic pulses to the load in high-power electrophysical facilities. The multimodule Angara-5-1 facility with an output electric power of up to 6 TW is considered. In this work, the experimental and calculated profiles of leakage currents in two sections of the line are compared when the eight-module facility is loaded by a wire array. The azimuthal distribution of the current in the cylindrical section of the MITL is also considered.

作者简介

E. Grabovski

Troitsk Institute for Innovation and Fusion Research

Email: Shishlov@triniti.ru
俄罗斯联邦, Troitsk, Moscow, 142190

A. Gribov

Troitsk Institute for Innovation and Fusion Research

Email: Shishlov@triniti.ru
俄罗斯联邦, Troitsk, Moscow, 142190

A. Samokhin

Troitsk Institute for Innovation and Fusion Research

Email: Shishlov@triniti.ru
俄罗斯联邦, Troitsk, Moscow, 142190

A. Shishlov

Troitsk Institute for Innovation and Fusion Research

编辑信件的主要联系方式.
Email: Shishlov@triniti.ru
俄罗斯联邦, Troitsk, Moscow, 142190

补充文件

附件文件
动作
1. JATS XML

版权所有 © Pleiades Publishing, Ltd., 2016