Methods for Studying Materials and Structures in Electronics as Applied to the Development of Medicinal Endoprostheses of Titanium with Enhanced Fibroinegration Efficiency
- Авторлар: Malinkovich M.1, Cherkesov I.2, Temirov A.1, Molchanov S.3, Shaikhaliev A.2, Polisan A.1, Ivanov S.2, Kiselev D.1, Parkhomenko Y.1
-
Мекемелер:
- National Research Technological University, Moscow Institute of Steel and Alloys
- Sechenov First Moscow State Medicinal University
- OOO Konmet
- Шығарылым: Том 47, № 8 (2018)
- Беттер: 575-582
- Бөлім: Article
- URL: https://journals.rcsi.science/1063-7397/article/view/187038
- DOI: https://doi.org/10.1134/S1063739718080103
- ID: 187038
Дәйексөз келтіру
Аннотация
Titanium alloys approved for clinical use in Russia are widely used in traumatology, maxillofacial surgery, and stomatology, mainly for manufacturing various endoprostheses and dental implants, i.e., structures to be introduced and installed into the bone and soft tissues of the human organism, capable of both biointegration and bioadaptation in the tissues of the human organism. In the field of medicinal material science, particularly, in designing structures for medicinal use based on titanium and its alloys and also various coatings on the surface of such structures, the modern methods and instruments developed for the electronic industry are being widely used. The methods designed for investigating materials and structures in electronics are employed in medicinal technology and particularly in the development of titanium implants. This makes it possible to develop the fundamentals for the technology of preparing the optimal microrelief on the surface of titanic endoprostheses intended for engrafting in soft tissues (i.e., fibrointegrable) and covered by bioactive coatings of titanium dioxide (TiO2) with the anatase structure obtained by atomic-layer deposition. The research is aimed at revealing the optimal surface treatment of such endoprostheses in order to achieve improved fibrointegration properties for using them in maxillofacial surgery. It is shown that the strong adhesion and fibrointegration between the titanium endoprosthesis and the connective tissue are achieved at the average surface roughness of (4–8) × 102 nm, the root-mean-square roughness of (5 × 102–1 × 103) nm, a profile height of (3–6) × 103 nm, and a thickness of the bioactive coatings of the order of magnitude of 10 nm.
Негізгі сөздер
Авторлар туралы
M. Malinkovich
National Research Technological University, Moscow Institute of Steel and Alloys
Хат алмасуға жауапты Автор.
Email: malinkovich@yandex.ru
Ресей, Moscow, 119049
I. Cherkesov
Sechenov First Moscow State Medicinal University
Email: malinkovich@yandex.ru
Ресей, Moscow, 119991
A. Temirov
National Research Technological University, Moscow Institute of Steel and Alloys
Email: malinkovich@yandex.ru
Ресей, Moscow, 119049
S. Molchanov
OOO Konmet
Email: malinkovich@yandex.ru
Ресей, Moscow, 125413
A. Shaikhaliev
Sechenov First Moscow State Medicinal University
Email: malinkovich@yandex.ru
Ресей, Moscow, 119991
A. Polisan
National Research Technological University, Moscow Institute of Steel and Alloys
Email: malinkovich@yandex.ru
Ресей, Moscow, 119049
S. Ivanov
Sechenov First Moscow State Medicinal University
Email: malinkovich@yandex.ru
Ресей, Moscow, 119991
D. Kiselev
National Research Technological University, Moscow Institute of Steel and Alloys
Email: malinkovich@yandex.ru
Ресей, Moscow, 119049
Yu. Parkhomenko
National Research Technological University, Moscow Institute of Steel and Alloys
Email: malinkovich@yandex.ru
Ресей, Moscow, 119049