Catalytic spectrophotometric determination of trace amount of cerium(IV)


如何引用文章

全文:

开放存取 开放存取
受限制的访问 ##reader.subscriptionAccessGranted##
受限制的访问 订阅存取

详细

Based on a property that in dilute hydrochloric acid hydrogen peroxide oxidizes Ponceau S to fade and cerium(IV) has a catalytic effect on the reaction, a new spectrophotometric method was developed for the determination of trace cerium(IV). At 450 nm, the cerium(IV) concentration presents a good linear relationship over the range of 0.08‒4 μg/mL with the fading degree ΔA. Its linear regression equation is ΔA = 0.0475c (μg/mL) + 0.0007, with a correlation coefficient of 0.9991. The detection limit of method is 0.05 μg/mL. The method has been successfully applied to the determination of cerium in water and molecular sieve samples with good results. The relative standard deviations of eleven determinations were 0.97‒1.11 and 0.19‒1.01%, respectively. The recoveries of standard additions were 99.4‒99.9 and 99.2‒101.0%, respectively. The reliability of this method was certified by parallel determination against the dibromo-p-chlorochlorophosphonazo spectrophotometry.

作者简介

Qing-Zhou Zhai

Research Center for Nanotechnology, South Campus

编辑信件的主要联系方式.
Email: zhaiqingzhou@163.com
中国, 7186 Weixing Road, Changchun, 130022

Wei-Hua Hu

Research Center for Nanotechnology, South Campus

Email: zhaiqingzhou@163.com
中国, 7186 Weixing Road, Changchun, 130022

Zhong Chai

Research Center for Nanotechnology, South Campus

Email: zhaiqingzhou@163.com
中国, 7186 Weixing Road, Changchun, 130022


版权所有 © Pleiades Publishing, Ltd., 2017