Determination of Melatonin Hormone and Neurotransmitters in Cerebrospinal Fluid: Method Validation and Uncertainty Calculations


Cite item

Full Text

Open Access Open Access
Restricted Access Access granted
Restricted Access Subscription Access

Abstract

The uncertainty of measurement for well-known neurotransmitters like serotonin, noradrenalin and gamma-aminobutyric acid (GABA), glutamate and melatonin hormone with high performance liquid chromatography−fluorescence detection was calculated after the method validation. Two methods were developed for the determination of the neurotransmitters. A derivatization step was performed for the determination of GABA and glutamate. Sensitivity, method detection limit, limit of quantification, linearity, recovery, interday and intraday precision values were calculated. Low detection limit values were obtained especially for the determination of GABA and glutamate. Then, bottom-up approach was used to calculate measurement uncertainty. The critical stages of the method were evaluated. The major sources of the uncertainty budget were calibration curves, stock solution and recovery. The calculated percentage relative uncertainty values for the compounds changed between 10.1 and 16.7.

About the authors

Özge Yetgin Çetin

Abant İzzet Baysal University, Faculty of Science and Art

Email: yenisoykarakas_s@ibu.edu.tr
Turkey, Gölköy, Bolu, 14030

Hatice Karadeniz

Abant İzzet Baysal University, Faculty of Science and Art

Email: yenisoykarakas_s@ibu.edu.tr
Turkey, Gölköy, Bolu, 14030

Alper Karakaş

Abant İzzet Baysal University, Faculty of Science and Art

Email: yenisoykarakas_s@ibu.edu.tr
Turkey, Gölköy, Bolu, 14030

Serpil Yenisoy-Karakaş

Abant İzzet Baysal University, Faculty of Science and Art

Author for correspondence.
Email: yenisoykarakas_s@ibu.edu.tr
Turkey, Gölköy, Bolu, 14030


Copyright (c) 2018 Pleiades Publishing, Ltd.

This website uses cookies

You consent to our cookies if you continue to use our website.

About Cookies