Investigation of a Two-Coordinate Gas-Discharge Detector of Slow Neutrons with a 10B Solid Converter
- Авторы: Potashev S.I.1, Burmistrov Y.M.1, Drachev A.I.1, Karaevsky S.K.1, Solodukhov G.V.1
-
Учреждения:
- Institute for Nuclear Research
- Выпуск: Том 12, № 3 (2018)
- Страницы: 627-631
- Раздел: Article
- URL: https://journals.rcsi.science/1027-4510/article/view/195670
- DOI: https://doi.org/10.1134/S102745101802012X
- ID: 195670
Цитировать
Аннотация
A two-coordinate detector based on a 10B layer and a gas-discharge chamber with a sensitive area of 128 mm2 and 3-mm-thick input and output windows intended for recording slow neutrons are investigated. The recording efficiency is more than 3% at a wavelength of 1.82 Å. The recording efficiency is estimated to be ~8% at a wavelength of 8 Å. The measured background contribution is less than 0.0001% of the thermal neutron one. For the Ar + 25%CO2 + 0.3%CF3Br gas mixture, the spatial resolution is about 2 mm along one of the coordinates under standard conditions. The neutron position is determined by the charge division method.