State Standards

State Primary Standard Get 55-2017 for Units of Sound Pressure and Vibrational Velocity in a Water Medium

Isaev A., Matveev A., Nekrich G., Nekrich S., Sil’vestrov S.

Resumo

We present the characteristics of GET 55-2017, the State Primary Standard for reproduction and transmission of units of sound pressure and vibrational velocity in a water medium. We consider the operational principles of installations, measurement formulas and the results of the investigation of metrological characteristics.

Measurement Techniques. 2017;60(8):751-754
pages 751-754 views

General Problems of Metrology and Measurement Technique

Generalized Extended Sequences for Integrated-Code Measurement Systems

Fedorov G., Tereshchenko S.

Resumo

A new extensive class of binary (0, 1)-sequences is proposed, which includes an infinite set of infinite sets of generalized extended sequences. These sequences are obtained by expanding inversion extended pseudorandom sequences. This enables the creation of coding collimators in integrated-code systems for measuring spatial distributions of radiation sources with the possibility of varying the average transmission and effective implementation of radiation-physics experiments using multiplexed measurements.

Measurement Techniques. 2017;60(8):755-762
pages 755-762 views

Article

Examination of Systematic Bench Errors for Calibration of a Strain-Gauge Balance

Bol’shakova A., Volobuev V., Gorbushin A., Petronevich V.

Resumo

We present a schematic diagram of the automated calibration stand 6GS-40M intended for calibration of an intra- and out-of-model six-component strain-gauge balance. The basic features of the stand construction are stated and its elastic model is constructed. The main sources of the occurrence of systematic errors in weights are considered. A technique for calculating the movement of the origin of the stand during the calibration of the balance is described. A technique for calculating loads in the Earth coordinate system is described by recording the equation of equilibrium of forces for an arbitrary position of the calibration device in space.

Measurement Techniques. 2017;60(8):763-770
pages 763-770 views

The Signal Function in the Objective of Improving the Accuracy of Radar-Tracking Measurements Taking Into Account Frequency Dispersion in Waveguides

Davydochkin V.

Resumo

Properties of the signal function that takes into account the frequency dispersion in an antenna waveguide path were studied. It was established that the measurement error of distance in a hollow waveguide is greater than the measurement error in free space. An increase is demonstrated in the permissible level of interference at which an estimation of the difference frequency signal relative to the frequency of the global maximum of the signal function is possible.

Measurement Techniques. 2017;60(8):785-793
pages 785-793 views

Improvement of Laser Rangefinders with Pulse Energy Safe for Human Eyes

Besogonov V.

Resumo

The characteristics of a laser rangefinder with a wavelength of 1.54 μm having a radiation pulse energy less than the threshold value safe for human eyes are calculated. Two examples of photodetectors with increased sensitivity are given. A system for pumping the laser active element by laser diode lines is proposed which increases the efficiency of the laser emitter and decreases the energy load on the active element.

Measurement Techniques. 2017;60(8):801-805
pages 801-805 views

Estimation of the Precision of Transmission of the Standard Signal of a Hydrogen Oscillator Along a Fiber-Optic Communication Line with Electronic Compensation of Disturbances

Balaev R., Malimon A., Fedorova D., Kurchanov A., Troyan V.

Resumo

An experimental plant for transmission of a reference signal along a fiber-optic communication line with electronic compensation of disturbances introduced by the line is described. Results of measurements of the error associated with transmission of the 100-MHz reference signal of the hydrogen oscillator of the State Primary Standard of the Units of Time and Frequency and the National Time Scale GET 1–2012 along a 100–200 km fiber-optic communication lines are presented.

Measurement Techniques. 2017;60(8):806-812
pages 806-812 views

Analysis of the Instability of the Frequency of the Signal of a Group of High-Stability Oscillators

Vasil’ev V., Pashev G.

Resumo

An analysis of the instability of the frequency of the output signal of a group frequency keeper is presented. The correlation between the signals of the high-frequency oscillators forming the group is taken into account. Formulas for use in calculating the Allan variation of the frequency of the group signal are obtained.

Measurement Techniques. 2017;60(8):813-817
pages 813-817 views

Comparative Analysis of Search Methods for the Source of a Magnetic Field of a Dipole Model

Ivanov Y., Semenov V.

Resumo

A detailed error analysis of input and output data for several rapid methods of magnetic search is carried out. Computer simulation is used to make comparative estimates of the accuracies and search ranges for a particular measurement situation. Scale modeling for searches and the application of these results to arbitrary measurement situations are discussed.

Measurement Techniques. 2017;60(8):823-830
pages 823-830 views

Planar Magnetotransistor with Compensation of Collector Current

Tikhonov R.

Resumo

The design of a magnetotransistor with two contacts to the base for the purpose of increasing the sensitivity of a planar magnetotransistor is investigated. The possibility of creating a magnetotransistor with compensation of collector currents based on the use of the technology of heterojunction bipolar transistors is considered.

Measurement Techniques. 2017;60(8):831-838
pages 831-838 views

Design and Investigation of an On-Board Gas Analyzer of Oxygen Partial Pressure

Voronova T., Lipnin Y., Mazur V., Pudalov A.

Resumo

We developed and studied an analytical oxygen solid electrolyte cell with hermetized gas reference medium. This cell can be used in on-board gas analyzers of oxygen partial pressure. The main stages of research and design works are presented. The procedures of calibration of the gas analyzer and adjustment of its sensor are performed. A small series of gas analyzers was produced and introduced with the help of the procedure of measurements based on the use of a solid electrolyte cell.

Measurement Techniques. 2017;60(8):853-856
pages 853-856 views

Nanometrology

A Dynamic Method of Nanoindentation

Meshcheryakov V., Maslennikov V., Melekesov E.

Resumo

A new dynamic method of measuring the local value of hardness and contact stiffness at the nanoscale range using a probe in self-oscillation mode at resonant eigenfrequency is proposed. The possibility is shown of measuring the force of contact interaction of a probe with a sample in a range from ten to several hundred μN with shift of the probe’s resonant eigenfrequency, at a resolution up to one hundred nN. The advantage of this method is the absence of a drift component of the measuring signal during the time interval of a test cycle. This ensures operability of the method without special conditions of vibration insulation and thermal insulation that are necessary for instrumental indentation.

Measurement Techniques. 2017;60(8):771-776
pages 771-776 views

Linear and Angular Measurements

Study of Filtration Error of Surface Texture Using a Gaussian Spatial Filter

Poroshin V., Bogomolov D., Lysenko V.

Resumo

Spatial filtration errors of surface texture by means of a Gaussian filter are analyzed. A composite model is used in a mathematical description of surface texture. The analytical dependence of Gaussian filtration error is derived. Errors are investigated in filtration of a sinusoidal wave and surface inclination.

Measurement Techniques. 2017;60(8):777-784
pages 777-784 views

Optophysical Measurements

Correlational Nonlinear Optical Femtosecond Laser Profilometer with Micrometer Spatial Resolution

Hovhannisyan D., Vardanyan A., Melikyan S., Savkin K., Tikhomirov S., Hovhannisyan G.

Resumo

A new femtosecond correlation nonlinear optical profilometer with micron spatial resolution is proposed, in order to increase the measurement accuracy of the heterogeneity profile of a surface at a distance up to 1 km. The principle of operation of this profilometer is based on determining the distance to the scanned object by measuring the time interval between sequences of the base (probing) and reflected femtosecond laser pulses. Thereafter, the profile of a rough surface is reestablished by using the one-dimensional spatial distribution of second-harmonic radiation as the space-time coupling of the sequences of the probing and reflected pulses in a nonlinear crystal is restored. It was shown that the spatial resolution of the profilometer is no greater than 5 μm.

Measurement Techniques. 2017;60(8):794-800
pages 794-800 views

Electromagnetic Measurements

Development and Study of a Pulsed Magnetic Induction Meter Based on Nuclear Magnetic Resonance for High Magnetic Fields

Neronov Y., Seregin N.

Resumo

A pulsed magnetic induction meter is developed for testing the static fields of magnets, electromagnets, and solenoids. The instrument error is 2·10–6 for fields on the order of 25 mT with field inhomogeneities of 7·10–5 within 1 cm.

Measurement Techniques. 2017;60(8):818-822
pages 818-822 views

Radio Measurements

Second-Generation Algorithm for Implementation of Method of Mirror Noise Images

Chernov E., Sobolev N., Stepanov V.

Resumo

A second-generation algorithm designed for implementation of the new method of mirror noise images for separating a useful signal from noise is proposed. By means of the method, a signal-to-noise ratio higher than the limiting values determined by the method of optimum filtration of signals used in classical radio engineering may be obtained. The results of the study of the algorithm show that it yields a substantial gain in the signal-to-noise ratio by comparison with narrow-band filtration of signals and the first-generation algorithm that implements the present method.

Measurement Techniques. 2017;60(8):839-842
pages 839-842 views

Ionizing Radiation Measurements

Infrared Method for Detection of Coherent Magnetic Bremsstrahlung in a Collider

Mal’tsev A., Mal’tseva M.

Resumo

A method is presented for detection of magnetic bremsstrahlung on colliding beams in colliders, particularly coherent bremsstrahlung in the area of low-energy photons in collision with high-energy particle beams. The properties of coherent bremsstrahlung and its capability for detection and use of beams in diagnostics are presented.

Measurement Techniques. 2017;60(8):843-847
pages 843-847 views

Physicochemical Measurements

Preparation of Calibration Gas Mixtures by the Chromato-Desorption Method for Increasing the Accuracy of Quantitative Determination of Biogenic Pentane in Expired Air

Platonov I., Kolesnichenko I., Novikova E., Pavlova L., Lobanova M., Mikheenkova A.

Resumo

The possibility of increasing the accuracy of preparing n-pentane calibration gas mixtures by using injection-type chromato-desorption microsystems is investigated. The possibility of obtaining calibration gas mixtures in the range of 4–12 mg/m3max = 16%) is shown. It is established that the change in the composition of the mixture during storage for three months is not more than 7%.

Measurement Techniques. 2017;60(8):848-852
pages 848-852 views