Evaluation of Antitumor Efficiency of High Intensity Radiation 169Yb Source on Experimental Sarcoma M-1


Cite item

Full Text

Open Access Open Access
Restricted Access Access granted
Restricted Access Subscription Access

Abstract

Rats with sarcoma M-1 were exposed to high dose rate irradiation with 169Yb source. In 25 days after introduction of a trocar with sealed capsule with 169Yb source into the tumor, complete tumor regression was observed in 70% animals. The results suggest feasibility of using 169Yb source for high-dose rate brachytherapy and development of the personalized medicine approaches.

About the authors

S. E. Ulyanenko

A. F. Tsyb Medical Radiological Research Center, Affiliated Branch of the National Medical Research Radiological Center, Ministry of Health of the Russian Federation

Email: korsenic@mail.ru
Russian Federation, Obninsk

S. N. Koryakin

A. F. Tsyb Medical Radiological Research Center, Affiliated Branch of the National Medical Research Radiological Center, Ministry of Health of the Russian Federation

Author for correspondence.
Email: korsenic@mail.ru
Russian Federation, Obninsk

A. A. Lychagin

A. F. Tsyb Medical Radiological Research Center, Affiliated Branch of the National Medical Research Radiological Center, Ministry of Health of the Russian Federation

Email: korsenic@mail.ru
Russian Federation, Obninsk

M. N. Kuznetsova

A. F. Tsyb Medical Radiological Research Center, Affiliated Branch of the National Medical Research Radiological Center, Ministry of Health of the Russian Federation

Email: korsenic@mail.ru
Russian Federation, Obninsk

V. I. Potetnya

A. F. Tsyb Medical Radiological Research Center, Affiliated Branch of the National Medical Research Radiological Center, Ministry of Health of the Russian Federation

Email: korsenic@mail.ru
Russian Federation, Obninsk

L. N. Ulyanenko

A. F. Tsyb Medical Radiological Research Center, Affiliated Branch of the National Medical Research Radiological Center, Ministry of Health of the Russian Federation

Email: korsenic@mail.ru
Russian Federation, Obninsk

A. I. Brovin

A. F. Tsyb Medical Radiological Research Center, Affiliated Branch of the National Medical Research Radiological Center, Ministry of Health of the Russian Federation

Email: korsenic@mail.ru
Russian Federation, Obninsk


Copyright (c) 2019 Springer Science+Business Media, LLC, part of Springer Nature

This website uses cookies

You consent to our cookies if you continue to use our website.

About Cookies