A clinical case of a combined method for correcting irregular post-keratoplastic astigmatism in a patient with cataract
- Authors: Sinitsyn M.V.1, Pozdeyeva N.A.1
-
Affiliations:
- S. Fyodorov Eye Microsurgery Federal State Institution, Cheboksary Branch
- Issue: Vol 16, No 2 (2023)
- Pages: 99-107
- Section: Case reports
- URL: https://journals.rcsi.science/ov/article/view/253841
- DOI: https://doi.org/10.17816/OV109620
- ID: 253841
Cite item
Abstract
Using the example of a clinical case, a clinical and functional analysis of a combined method for correcting irregular post-keratoplastic astigmatism in a patient with cataract is presented.
Patient, aged 50, complained of low vision and fog in front of the left eye during the last 3 years. For the left eye, the diagnosis was made: “Irregular post-keratoplastic astigmatism of a high degree, condition after penetrating keratoplasty, posterior capsular cataract.” To correct the irregular post-keratoplastic astigmatism, the patient underwent the MyoRing implantation into the corneal graft. Then, 1 year later, the patient underwent cataract phacoemulsification with a toric intraocular lens implantation for the simultaneous correction of residual corneal astigmatism. The follow-up period after phacoemulsification was 1 year. One year after the MyoRing implantation into the corneal graft, uncorrected visual acuity and corrected visual acuity increased from 0.02 to 0.05, corneal astigmatism decreased by 4.46 D and became significantly more regular. 1 month after phacoemulsification with toric intraocular lens implantation, uncorrected visual acuity increased from 0.05 to 0.8, corrected visual acuity — from 0.05 to 1.0; spherical and cylindrical components of refraction amounted to –0.5 D each and did not change anymore.
The combined method of irregular post-keratoplastic astigmatism correction in a patient with cataract showed a high refractive result, stability and safety in the late postoperative period.
Full Text
##article.viewOnOriginalSite##About the authors
Maksim V. Sinitsyn
S. Fyodorov Eye Microsurgery Federal State Institution, Cheboksary Branch
Author for correspondence.
Email: mntksinicin@mail.ru
ORCID iD: 0000-0002-7285-1782
Cand. Sci. (Med.), MD of highest qualification
Russian Federation, CheboksaryNadezhda A. Pozdeyeva
S. Fyodorov Eye Microsurgery Federal State Institution, Cheboksary Branch
Email: mntksinicin@mail.ru
ORCID iD: 0000-0003-3637-3645
MD, Dr. Sci. (Med.), assistant professor
Russian Federation, CheboksaryReferences
- Suchismitha T. Penetrating keratoplasty with minimal endothelial replacement: a novel technique for high-risk large-diameter corneal grafting. Cornea. 2022;41(2):264–268. doi: 10.1097/ICO.0000000000002875
- Senchenko NYa, Shanturova MA, Mishchenko OP, Zaytseva KA. Results of “Material for cornea restoration” application in various types of keratoplasty. Practical medicine. 2017;(9–1):88–91. (In Russ.)
- Jusufovic V, Cabric E, Vodencarevic AN. Simultaneous penetrating keratoplasty, cataract removal and intraocular lens implantation in Tuzla, Bosnia and Herzegovina. Med Arch. 2019;73(2):123–125. doi: 10.5455/medarh.2019.73.123-125
- Pellegrini M, Furiosi L, Yu AC, et al. Outcomes of cataract surgery with toric intraocular lens implantation after keratoplasty. J Cataract Refract Surg. 2022;48(2):157–161. doi: 10.1097/j.jcrs.0000000000000730
- Müftüoğlu İK, Akova YA, Egrilmez S, Yilmaz SG. The results of toric intraocular lens implantation in patients with cataract and high astigmatism after penetrating keratoplasty. Eye Contact Lens. 2016;42(2): e8–e11. doi: 10.1097/ICL.0000000000000147
- Cung LX, Hang DT, Hiep NX, et al. Evaluation of phacoemulsification cataract surgery outcomes after penetrating keratoplasty. Open Access Maced J Med Sci. 2019;7(24):4301–4305. doi: 10.3889/oamjms.2019.379
- Nuzzi R, Monteu F. Correction of high astigmatism after penetrating keratoplasty with toric multifocal intraocular lens implantation. Case Rep Ophthalmol. 2017;8(2):385–388. doi: 10.1159/000478518
- Daxer A. Adustable intracorneal ring in a corneal pocket for keratoconus. J Refract Surg. 2010;26(3):217–221. doi: 10.3928/1081597X-20100224-08
- Patent RUS № 2737221/ 26.11.2020. Byul. № 33. Pozdeyeva NA, Kulikova IL, Sinitsyn MV, et al. Sposob korrektsii indutsirovannogo postkeratoplasticheskogo astigmatizma i miopii vysokoi stepeni (cited 2023 March 30). Available from: https://patenton.ru/patent/RU2737221C1(In Russ.)
- Pozdeyeva NA, Kulikova IL, Sinitsyn MV, Terentieva AE. Induced astigmatism and concomitant high myopia correction with femtosecond laser-assisted intrastromal MyoRing implantation. Fyodorov journal of ophthalmic surgery. 2020;(4):73–76. (In Russ.) doi: 10.25276/0235-4160-2020-4-73-76
- Application for an invention № 2022111317/ 26.04.2022. Pozdeyeva NA, Sinitsyn MV. Sposob rascheta opticheskoi sily intraokulyarnoi linzy pri ehkstraktsii katarakty u patsienta posle implantatsii intrastromalnogo koltsa MyoRing v rogovichnyi transplantat. (In Russ.)
- Malyugin BE, Tokmakova AN, Karimova АN. Long-term results of laser correction of astigmatism after penetrating keratoplasty in patients with keratoconus. Practical medicine. 2017;(9–2):128–133. (In Russ.)
- Slonimskiy AYu. Transparent keratoplasty and excimer laser correction of postkeratoplastic ametropy. Russian journal of clinical ophthalmology. 2004;(3):98. (In Russ.)
- Donoso R, Díaz C, Villavicencio P. Long-term results of LASIK refractive error correction after penetrating keratoplasty in patients with keratoconus. Arch Soc Esp Oftalmol. 2016;90(7):308–311. doi: 10.1016/j.oftale.2015.07.012
- Tolchinskaya AI. Prichiny rogovichnykh oslozhnenii v otdalennom periode nablyudeniya afakichnogo i artifakichnogo glaza i mery ikh profilaktiki [dissertation]. Moscow, 1988. (In Russ.)
- Bourne WM, Carey BE, Kaufman HE. Clinical specular microscopy. Am J Ophthalmol. 1976;81(3):743–753. doi: 10.1016/0002-9394(76)90247-6