Contrast sensitivity in patients with monofocal and multifocal pseudophakia at spherical defocus of different degrees


Cite item

Full Text

Open Access Open Access
Restricted Access Access granted
Restricted Access Subscription Access

Abstract

In the present article, authors evaluate the influence of spherical defocus on contrast sensitivity level in patients with monofocal vs bifocal pseudophakia. The study included 27 patients (30 eyes) after cataract surgery, in whom contrast sensitivity in the setting of different illumination conditions at spherical defocus of different degree and sign was tested. To measure contrast sensitivity Optec® 6500 was used. Mann-Whitney U-test was used to compare results between groups. It was established that illumination level and defocus degree exert different influence on contrast sensitivity in patients with monofocal and bifocal pseudophakia.

About the authors

Yury Viktorovich Takhtaev

North-Western State Medical University n.a. I. I. Mechnikov

Email: Yurii.Takhtaev@spbmapo.ru
MD, PhD, Doc.Med.Sci., professor, head of the ophthalmology department

Elena Gennadyevna Bogachuk

North-Western State Medical University n.a. I. I. Mechnikov

Email: begrun@mail.ru
MD, aspirant. Ophthalmology Department

References

  1. Даниличев В. Ф. Современная офтальмология: Руководство. 2-е изд. Под ред. В. Ф. Даниличева. СПб.: Питер; 2009.
  2. Даниличев В. Ф., Колесникова Л. Н., Шелепин Ю. В., Александров А. С. Визоконтрастометрия при травме. В кн.: Повреждение органа зрения. Труды ВМА. 1986; 226: 47-51.
  3. Даниличев В. Ф., Шелепин Ю. В. Визоконтрастометрия как современный способ определения тяжести повреждений сетчатки. Воен.-мед. журн. 1992; 3: 33-34.
  4. Сомов Е. Е., Гацу М. В. Способ диагностики скрытых форм симпатического нейроретинита. В кн.: Повреждения органа зрения у детей: Сб. науч. тр. Под ред. Е. Е. Сомова. СПб.; 1991: 25-30.
  5. Awwad S. T., Warmerdam D., Bowman R. W. et al. Contrast sensitivity and higher order aberrations in eyes implanted with Acrysof IQ SN60WF and AcrySof SN60AT intraocular lenses. J. Refract. Surg. 2008; 24: 619-625.
  6. Bellucci R., Scialdone A., Buratto L. et al. Visual acuity and contrast sensitivity comparison between Tecnis and AcrySof SA60AT intraocular lenses: a multicenter randomized study. J. Cataract. Refract. Surg. 2005; 31: 712-717.
  7. Caporossi A., Martone G., Casprini F., Rapisarda L. Prospective randomized study of clinical performance of 3 aspheric and 2 spherical intraocular lenses in 250 eyes. J. Refract. Surg. 2007; 23: 639-648.
  8. Dick H. B. Recent development in aspheric intraocular lenses. Curr. Opin. Ophthalmol. 2009; 20: 25-32.
  9. Ginsburg A. P. Contrast sensitivity and functional vision. Int. Ophthalmol. Clin. 2003; 43 (2): 5-15.
  10. Holladay J. T., Piers P. A., Koranyi G. et al. A new intraocular lens design to reduce spherical aberration of pseudophakic eyes. J. Refract. Surg. 2002; 18: 683-691.
  11. Kershner R. M. Retinal image contrast and functional visual performance with aspheric, silicone, and acrylic intraocular lenses; prospective evaluation. J. Cataract. Refract. Surg. 2003; 29: 1684-1694
  12. Mester U., Dillinger P., Anterist N. Impact of a modified optic design on visual function: clinical comparative study. J. Cataract. Refract. Surg. 2003; 29: 652-660.
  13. Mester U., Kaymak H. Comparison of the AcrySof IQ aspheric blue light filter and the Acrysof SA60AT intraocular lenses. J. Refract Surg. 2008; 24: 817-825.
  14. Packer M., Fine H., Hoffman R. S., Piers P. A. Prospective randomized trial of an anterior surface modified prolate intraocular lens. J Refract Surg. 2002; 18: 692-696.
  15. Pandita D., Raj S. M., Vasavada V. A. et al. Contrast sensitivity and glare disability after implantation of AcrySof IQ Natural aspherical intraocular lens: prospective randomized masked clinical trial. J. Cataract Refract Surg. 2007; 33: 603-610.
  16. Schmitz S., Dick H. B., Krummenauer F. et al. Contrast sensitivity and glare disability by halogen light after monofocal and multifocal lens implantation. Br J Ophthalmol 2000; 84: 1109-1112. doi: 10.1136/bjo. 84.10.1109
  17. Parede T. R. R., Torricelli A. A. M., Mukai A. et al. Quality of vision in refractive and cataract surgery, indirect measurers: review article. Arq. Bras. Oftalmol. 2013; 76(6): 386-390.
  18. Tzelikis P. F., Akaishi L., Trindade F. C., Boteon J. E. Ocular aberrations and contrast sensitivity after cataract surgery with AcrySof IQ intraocular lens implantation; clinical comparative study. J Cataract Refract Surg. 2007; 33: 1918-1924.
  19. Tzelikis P. F., Akaishi L., Trindade F. C., Boteon J. E. Spherical aberration and contrast sensitivity in eyes implanted with aspheric and spherical intraocular lenses: a comparative study. Am. J. Ophthalmol. 2008; 145: 827-833.

Supplementary files

Supplementary Files
Action
1. JATS XML

Copyright (c) 2015 Takhtaev Y.V., Bogachuk E.G.

Creative Commons License
This work is licensed under a Creative Commons Attribution 4.0 International License.
 


Согласие на обработку персональных данных с помощью сервиса «Яндекс.Метрика»

1. Я (далее – «Пользователь» или «Субъект персональных данных»), осуществляя использование сайта https://journals.rcsi.science/ (далее – «Сайт»), подтверждая свою полную дееспособность даю согласие на обработку персональных данных с использованием средств автоматизации Оператору - федеральному государственному бюджетному учреждению «Российский центр научной информации» (РЦНИ), далее – «Оператор», расположенному по адресу: 119991, г. Москва, Ленинский просп., д.32А, со следующими условиями.

2. Категории обрабатываемых данных: файлы «cookies» (куки-файлы). Файлы «cookie» – это небольшой текстовый файл, который веб-сервер может хранить в браузере Пользователя. Данные файлы веб-сервер загружает на устройство Пользователя при посещении им Сайта. При каждом следующем посещении Пользователем Сайта «cookie» файлы отправляются на Сайт Оператора. Данные файлы позволяют Сайту распознавать устройство Пользователя. Содержимое такого файла может как относиться, так и не относиться к персональным данным, в зависимости от того, содержит ли такой файл персональные данные или содержит обезличенные технические данные.

3. Цель обработки персональных данных: анализ пользовательской активности с помощью сервиса «Яндекс.Метрика».

4. Категории субъектов персональных данных: все Пользователи Сайта, которые дали согласие на обработку файлов «cookie».

5. Способы обработки: сбор, запись, систематизация, накопление, хранение, уточнение (обновление, изменение), извлечение, использование, передача (доступ, предоставление), блокирование, удаление, уничтожение персональных данных.

6. Срок обработки и хранения: до получения от Субъекта персональных данных требования о прекращении обработки/отзыва согласия.

7. Способ отзыва: заявление об отзыве в письменном виде путём его направления на адрес электронной почты Оператора: info@rcsi.science или путем письменного обращения по юридическому адресу: 119991, г. Москва, Ленинский просп., д.32А

8. Субъект персональных данных вправе запретить своему оборудованию прием этих данных или ограничить прием этих данных. При отказе от получения таких данных или при ограничении приема данных некоторые функции Сайта могут работать некорректно. Субъект персональных данных обязуется сам настроить свое оборудование таким способом, чтобы оно обеспечивало адекватный его желаниям режим работы и уровень защиты данных файлов «cookie», Оператор не предоставляет технологических и правовых консультаций на темы подобного характера.

9. Порядок уничтожения персональных данных при достижении цели их обработки или при наступлении иных законных оснований определяется Оператором в соответствии с законодательством Российской Федерации.

10. Я согласен/согласна квалифицировать в качестве своей простой электронной подписи под настоящим Согласием и под Политикой обработки персональных данных выполнение мною следующего действия на сайте: https://journals.rcsi.science/ нажатие мною на интерфейсе с текстом: «Сайт использует сервис «Яндекс.Метрика» (который использует файлы «cookie») на элемент с текстом «Принять и продолжить».