The influence of phacoemulsification on the intraocular pressure level in patients with co-existing cataract and open-angle glaucoma

Cover Page

Cite item

Full Text

Abstract

Based on the examination and treatment results of 94 patients (100 eyes) with cataract and open-angle glaucoma, an estimation of phacoemulsification with intraocular lens implantation influence on the intraocular pressure level was performed. The result analysis showed that phacoemulsification in patients with co-existing cataract and stabilized open-angle glaucoma could ensure a pressure-lowering effect by continued local treatment consisting in instillations of modern IOP-lowering medications.

About the authors

Yana Yuryevna Mantseva

I. P. Pavlov State Medical University

Email: yana_man@mail.ru
post-graduate, Dep. of Ophthalmology

Sergey Yuryevich Astakhov

I. P. Pavlov State Medical University

Email: astakhov@spmu.rssi.ru
doctor of medical science, professor, Department of Ophthalmology

Polina Valeryevna Ananyevskaya

St. Petersburg State University

Email: ansk.p.v@gmail.com
post-graduate, Statistical Simulation Dep., Faculty of Mathematics and Mechanics

Aleksandra Ivanovna Titarenko

I. P. Pavlov State Medical University

Email: aleksandra-titarenko@yandex.ru
student, Dep. of Ophthalmology

References

  1. Курышева Н. И. Псевдоэксфолиативный синдром // Вестн. офтальмол. 2001. — T.117, № 3. — С. 47–50.
  2. Augustinus C. J., Zeyen T. The effect of phacoemulsification and combined phaco/glaucoma procedures on the intraocular pressure in open-angle glaucoma. A review of the literature // Bull. Soc. Belge Ophtalmol. — 2012. — N 320. — P. 51–66.
  3. Davanger M., Ringvold A., Blika S. Pseudo-exfoliation, IOP and glaucoma // Acta Ophthalmol. (Copenh.). — 1991. — Vol. 69, N 5. — P. 569–573.
  4. Choi D., Suramethakul P., LindsromR. L., Singh K. Glaucoma surgery with and without cataract surgery: Revolution or evolution? // J. Cataract Refract. Surg. — 2012. — Vol. 38, N 7. — P. 1121–1122.
  5. Chylack L. T., Wolfe J. K., Singer D. M. et al. Longitudinal Study of Cataract Study Group. The Lens Opacities Classification System III //Arch. Ophthalmol. — 1993. — Vol. 111, N 6. — P. 831–836.
  6. Grehn F., Klink T. Management of glaucoma and cataract. Principles and Practice of Ophthalmology. Third edition. — Elsiever, 2008. — Vol. 2. — P. 2849–2858.
  7. Fogagnolo P., Centofanti M., Figus M. et al. Short-term changes in intraocular pressure after phacoemulsification in glaucoma patients // Ophthalmologica. — 2012. — Vol. 228, N 3. — P. 154–158.
  8. Hudovernik M., Pahor D. M. Intraocular pressure after phacoemulsification with posterior chamber lens implantation in open-angle glaucoma // Klin. Monatsbl. Augenheilkunde. — 2003. — N 220. — P. 835–839.
  9. Jamil A. Z., Iqbal K., Ur. Rahman F., Mirza K. A. J Effect of phacoemulsification on intraocular pressure // Coll Physicians Surg. Pak. — 2011. — Vol. 21, N 6. — P. 347–350.
  10. Jünemann A. G. Diagnosis and therapy of pseudoexfoliation glaucoma // Ophthalmol. — 2012. — Vol. 109. — N 10. — P. 962–975.
  11. Lundström M., Barry P., Henry Y. et al. Evidence-based guidelines for cataract surgery: Guidelines based on data in the European Registry of Quality Outcomes for Cataract and Refractive Surgery database // J. Cataract Refract. Surg. — 2012. — Vol. 38, N 6. — P. 1086–1093.
  12. Mansberger S. L., Gordon M. O., Jampel H. et al. Reduction in intraocular pressure after cataract extraction: the Ocular Hypertension Treatment Study // Ophthalmol. — 2012. — Vol. 119, N 9. — P. 1826–1831.
  13. Mathalone N., Hyams M., Neiman S. et al. Long-term intraocular pressure control after clear corneal phacoemulsification in glaucoma patients // Cataract Refract Surg. — 2005. — Vol. 31, N 3. — P. 479–483.
  14. Merkur A., Damji K. F., Mintsioulis G., Hodge W. G. Intraocular pressure decrease after phacoemulsification in patients with pseudoexfoliation syndrome // J. Cataract. Refract. Surg. — 2001. — N 27. — P. 528–532.
  15. Mierzejewski A., Eliks I., KałuznyB. et al. Cataract phacoemulsification and intraocular pressure in glaucoma patients // Klin. Oczna. — 2008. — Vol. 110, N 1–3. — P. 11–17.
  16. Poley B. J., Lindstrom R. L., Samuelson T. W., Shulze R. Intraocular pressure reduction after phacoemulsification with intraocular lens implantation in glaucomatous eyes: evaluation of a casual relationship between the natural lens and open-angle glaucoma // J. Cataract Refract. Surg. — 2009. — Vol.35, N 6. — P. 1946–1955.
  17. Shingleton B. J., Gamell L. S., O’Donoghue M. W. et al. Long-term changes in intraocular pressure after clear corneal phacoemulsification: normal patients versus glaucoma suspect and glaucoma patients // J. Cataract Refract. Surg. — 1999. — Vol.25, N 7. — P. 885–890.
  18. Shrivastava A., Singh K. The effect of cataract extraction on intraocular pressure // Curr. Opin. Ophthal. — 2010. — Vol. 21. — P. 118–122.
  19. Thirumalai B., Baranyovits P. R. Intraocular pressure changes and the implications on patient review after phacoemulsification // J. Cataract Refract.Surg. — 2003. — Vol. 29, N 3. — P. 504–507.
  20. Yasutani H., Hayashi K., Hayashi H., Hayashi F. Intraocular pressure rise after phacoemulsification surgery in glaucoma patients / /J. Cataract Refract. Surg. — 2004. — Vol. 30, N 6. — P. 1219–1224.

Supplementary files

Supplementary Files
Action
1. JATS XML

Copyright (c) 2013 Mantseva Y.Y., Astakhov S.Y., Ananyevskaya P.V., Titarenko A.I.

Creative Commons License
This work is licensed under a Creative Commons Attribution 4.0 International License.
 


Согласие на обработку персональных данных с помощью сервиса «Яндекс.Метрика»

1. Я (далее – «Пользователь» или «Субъект персональных данных»), осуществляя использование сайта https://journals.rcsi.science/ (далее – «Сайт»), подтверждая свою полную дееспособность даю согласие на обработку персональных данных с использованием средств автоматизации Оператору - федеральному государственному бюджетному учреждению «Российский центр научной информации» (РЦНИ), далее – «Оператор», расположенному по адресу: 119991, г. Москва, Ленинский просп., д.32А, со следующими условиями.

2. Категории обрабатываемых данных: файлы «cookies» (куки-файлы). Файлы «cookie» – это небольшой текстовый файл, который веб-сервер может хранить в браузере Пользователя. Данные файлы веб-сервер загружает на устройство Пользователя при посещении им Сайта. При каждом следующем посещении Пользователем Сайта «cookie» файлы отправляются на Сайт Оператора. Данные файлы позволяют Сайту распознавать устройство Пользователя. Содержимое такого файла может как относиться, так и не относиться к персональным данным, в зависимости от того, содержит ли такой файл персональные данные или содержит обезличенные технические данные.

3. Цель обработки персональных данных: анализ пользовательской активности с помощью сервиса «Яндекс.Метрика».

4. Категории субъектов персональных данных: все Пользователи Сайта, которые дали согласие на обработку файлов «cookie».

5. Способы обработки: сбор, запись, систематизация, накопление, хранение, уточнение (обновление, изменение), извлечение, использование, передача (доступ, предоставление), блокирование, удаление, уничтожение персональных данных.

6. Срок обработки и хранения: до получения от Субъекта персональных данных требования о прекращении обработки/отзыва согласия.

7. Способ отзыва: заявление об отзыве в письменном виде путём его направления на адрес электронной почты Оператора: info@rcsi.science или путем письменного обращения по юридическому адресу: 119991, г. Москва, Ленинский просп., д.32А

8. Субъект персональных данных вправе запретить своему оборудованию прием этих данных или ограничить прием этих данных. При отказе от получения таких данных или при ограничении приема данных некоторые функции Сайта могут работать некорректно. Субъект персональных данных обязуется сам настроить свое оборудование таким способом, чтобы оно обеспечивало адекватный его желаниям режим работы и уровень защиты данных файлов «cookie», Оператор не предоставляет технологических и правовых консультаций на темы подобного характера.

9. Порядок уничтожения персональных данных при достижении цели их обработки или при наступлении иных законных оснований определяется Оператором в соответствии с законодательством Российской Федерации.

10. Я согласен/согласна квалифицировать в качестве своей простой электронной подписи под настоящим Согласием и под Политикой обработки персональных данных выполнение мною следующего действия на сайте: https://journals.rcsi.science/ нажатие мною на интерфейсе с текстом: «Сайт использует сервис «Яндекс.Метрика» (который использует файлы «cookie») на элемент с текстом «Принять и продолжить».