MRI-ASSESSMENT OF COMPOSITE INTERFERENCE SCREWS AFTER RECONSTRUCTION OF THE ANTERIORCRUCIATE LIGAMENT

Cover Page

Cite item

Full Text

Abstract

In the article authors describe the results of MRI studies of patients after reconstruction of the anterior cruciate ligament. The potential of biodegradable implants, timing of their location in the bone. The evaluation of bone response to biodegradable screws. The authors defined the terms of biodegradation clips from polylactic acid polymer and tricalcium phosphate.

About the authors

E A Dzhambinova

Федеральный научно-клинический центр специализированных видов медицинской помощи и медицинских технологий ФМБА России

клинический ординатор кафедры травматологии и ортопедии РУДН.

E A Zvezdkina

Федеральный научно-клинический центр специализированных видов медицинской помощи и медицинских технологий ФМБА России

ассистент кафедры лучевой диагностики Института Последипломного Образования ФМБА России, врач-рентгенолог ФНКЦ ФМБА России, к.м.н.

A A Akhpashev

Федеральный научно-клинический центр специализированных видов медицинской помощи и медицинских технологий ФМБА России

доцент кафедры травматологии, ортопедии и артрологии ФПК МР РУДН, к.м.н.

D S Agzamov

Федеральный научно-клинический центр специализированных видов медицинской помощи и медицинских технологий ФМБА России

д.м.н., проф., заведующий отделением травматологии и ортопедии ФНКЦ ФМБА России

V N Lesnyak

Федеральный научно-клинический центр специализированных видов медицинской помощи и медицинских технологий ФМБА России

заведующий рентгеновским отделением с кабинетами МРТ ФНКЦ ФМБА России

References

  1. Загородний Н.В., Королев А.В., Ахпашев А.А., Ильин Д.О., Хасаншин М.М. Поведение имплантатов в костной ткани согласно МРТ-исследованию. Журнал новости травматологии и ортопедии РУДН, 1-е издание, 2010.
  2. Weiler A, Hoffman RF, Stähelin AC, Bail HJ, Siepe CJ, Südkamp NP. Hamstring tendon fixation using interference screws: a biomechanical study in calf tibial bone. Arthroscopy. 1998; 14(1): 29-37.
  3. Walton M. Absorbable and metal interference screws: comparison of graft security during healing. Arthroscopy. 1999; 15(8):818-26.
  4. Caborn NM, Urban WP Jr, Johnson DL, Nyland J, Pienkowski D. Biomechanical comparison between Bioscrew and titanium alloy interference screws for bone patellar tendon-bone graft fixation in anterior cruciate ligament reconstruction. Arthroscopy. 1997; 13(2):229-32.
  5. McGuire DA, Barber FA, Elrod BF, Paulos LE. Bioabsorbable interference screws for graft fixation in anterior ligament reconstruction. Arthroscopy. 1999; 15(5):463-73.
  6. Marti C, Imhoff AB, Bahrs C, Romero J. Metallic versus bioabsorbable interference screw for fixation of bone-patellar tendon-bone autograft in arthroscopic ACL reconstruction. A preliminary report. Knee Surg Sports Traumatol Arthrosc. 1997; 5(4):217-21.
  7. Keading C, Farr J, Kavanaugh T, Pedroza A. A prospective randomized comparison of bioabsorbable and titanium anterior cruciate ligament interference screws. Arthroscopy. 2005; 21(2):147-151.
  8. Benedetto KP, Fellinger M, Lim TE, Passler JM, Schoen JL, Willems WJ. A new bioabsorbable interference screw: preliminary results of a prospective, multicenter, randomized clinical trial. Arthroscopy. 2000; 16(1):41-48.
  9. Weiler A, Peine R, Pashmineh-Azar A, Abel C, Südkamp NP, Hoffmann RF. Tendon healing in a bone tunnel, I: biomechanical results after biodegradable interference fit fixation in a model of ACL reconstruction in sheep.Arthroscopy. 2002; 18(2):113-123.
  10. Warden WH, Friedman R, Teresi LM, Jackson DW. Magnetic resonance imaging of bioabsorbable polylactic acid interference screws during the first two years after ACL reconstruction. Arthroscopy. 1999; 15(5):474-80.
  11. Drogset JO, Grøntvedt T, Myhr G. Magnetic resonance imaging analysis of bioabsorbable interference screws used for fixation of bone-patellar tendon-bone autografts in endoscopic reconstruction of the anterior cruciate ligament. Am J Sports Med. 2006; 34(7):1164-69.
  12. Lajtai G, Humer K, Aitzetmüller G, Unger F, Noszian I, Orthner E. Serial magnetic resonance imaging evaluation of a bioabsorbable interference screw and the adjacent bone. Arthroscopy. 1999; 15(5):481-8.
  13. Lajtai G, Noszian I, Humer K, Unger F, Aitzetmüller G, Orthner E. Serial magnetic resonance imaging evaluation of operative site after fixation of patellar tendon graft with bioabsorbable interference screws in anterior cruciate ligament reconstruction. Arthroscopy. 1999; 15(7):709-18.
  14. Lajtai G, Schmiedhuber G, Aitzetmuller G, et al. Bone tunnel remodeling at the site of biodegradable interference screws used for anterior cruciate ligament reconstruction: 5-year follow-up. Arthroscopy. 2001; 17(6):597-602.
  15. Fink C, Benedetto KP, Hackl W, Hoser C, Freund MC, Rieger M. Bioabsorbable polyglyconate interference screw fixation in anterior cruciate ligament reconstruction: a prospective computed tomography-controlled study. Arthroscopy. 2000; 16(5): 491-98.
  16. Ma CB, Francis K, Towers J, Irrgang J, Fu FH, Harner CH. Hamstring ACL reconstruction: a comparison of bioabsorbable interference screw and endo button fixation. Arthroscopy. 2004; 20(2):122-28.
  17. Buelow J, Siebold R, Ellermann A. A prospective evaluation of tunnel enlargement in anterior cruciate ligament reconstruction with hamstrings: extracortical versus anatomical fixation. Knee Surg, Sports Traumatol, Arthrosc. 2002; 10(2):80-85.
  18. Radford M, Noakes J, Read J, Wood DG. The natural history of a bioabsorbable interference screws used for anterior cruciate ligament reconstruction with a 4-strand hamstring technique. Arthroscopy. 2005; 21(6):707-10.
  19. Weiler A, Hoffman R, Stahelin A, Helling HJ. Biodegradable implants in sports medicine: the biologic base. Arthroscopy. 2000; 16:305-21.
  20. Morgan CD, Gehrmann RM, Jayo MJ, Johnson CS. Histologic findings with a bioabsorbable anterior cruciate ligament interference screw explant after 2.5 years in vivo. Arthroscopy. 2002; 18(9):E47.

Copyright (c) 2015 Dzhambinova E.A., Zvezdkina E.A., Akhpashev A.A., Agzamov D.S., Lesnyak V.N.

Creative Commons License
This work is licensed under a Creative Commons Attribution-NonCommercial-ShareAlike 4.0 International License.

This website uses cookies

You consent to our cookies if you continue to use our website.

About Cookies