In recent decades, the number of intracardiac procedures using percutaneous puncture access has increased manifold. Despite the acquisition by operators of expertise and standardization of methods, the problem of complications remains relevant.

AIM: to analyze the frequency and nature of complications of percutaneous access in intracardiac interventions. Suggest recommendations to reduce the incidence of complications.

MATERIALS AND METHODS: analysis of data published in international peer-reviewed journals on the topic, as well as the experience of the vascular surgery clinic of St. Katarina's Hospital.

CONCLUSIONS: the frequency and severity of complications depend on the experience of the operator, the size and frequency of changing the instrument, as well as compliance with the rules of preoperative diagnosis and postoperative management of the patient.

RECOMMENDATIONS: standardized preoperative preparation, careful planning of the intervention, analysis of the state of the access vessels, compliance with the rules of vessel puncture and competent performance of postoperative compression in combination with the use of suturing devices according to indications can reduce the frequency and severity of complications.

作者简介

Alexander Kimkov

St.-Katharinen Hospital GmbH Frechen

编辑信件的主要联系方式.
Email: alexandre04@inbox.ru
ORCID iD: 0000-0002-1774-938X

doctor of medical sciences

德国, Germany

参考

  1. Radner S. Thoracal aortography by catheterization from the radial artery; preliminary report of a new technique. Acta radiol. 1948;29(2):178–180. doi: 10.3109/00016924809132437
  2. Seldinger SI. Catheter replacement of the needle in percutaneous arteriography; a new technique. Acta radiol. 1953;39(5):368–376. doi: 10.3109/00016925309136722
  3. Kiemeneij F, Laarman GJ. Percutaneous transradial artery approach for coronary stent implantation. Cathet Cardiovasc Diagn. 1993;30(2):173–178. doi: 10.1002/ccd.1810300220
  4. Campeau L. Percutaneous radial artery approach for coronary angiography. Cathet Cardiovasc Diagn. 1989;16(1):3–7. doi: 10.1002/ccd.1810160103
  5. Mansour M, Karst E, Heist EK, et al. The Impact of First Procedure Success Rate on the Economics of Atrial Fibrillation Ablation. JACC: Clinical Electrophysiology. 2017;3(2):129–138. doi: 10.1016/j.jacep.2016.06.002
  6. Byrne RA, Cassese S, Linhardt M, Kastrati A. Vascular access and closure in coronary angiography and percutaneous intervention. Nat Rev Cardiol. 2013;10:27–40. doi: 10.1038/nrcardio.2012.160
  7. Waksman R, King SB III, Douglas JS, et al. Predictors of groin complications after balloon and new-device coronary intervention. Am J Cardiol. 1995;75(14):886–889. doi: 10.1016/s0002-9149(99)80681-x
  8. Omoigui NA, Califf RM, Pieper K, et al. Peripheral vascular complications in the Coronary Angioplasty Versus Excisional Atherectomy Trial (CAVEAT-I). J Am Coll Cardiol. 1995;26(4):922–930. doi: 10.1016/0735-1097(95)00263-4
  9. Piper WD, Malenka DJ, Ryan TJ Jr., et al. Predicting vascular complications in percutaneous coronary interventions. Am Heart J. 2003;145(6):1022–1029. doi: 10.1016/S0002-8703(03)00079-6
  10. Dauerman HL, Applegate RJ, Cohen DJ. Vascular closure devices: the second decade. J Am Coll Cardiol. 2007;50(17):1617–1626. doi: 10.1016/j.jacc.2007.07.028
  11. Marso SP, Amin AP, House JA, et al. Association between use of bleeding avoidance strategies and risk of periprocedural bleeding among patients undergoing percutaneous coronary intervention. JAMA. 2010;303(21):2156–2164. doi: 10.1001/jama.2010.708
  12. Tavris DR, Gallauresi BA, Lin B, et al. Risk of local adverse events following cardiac catheterization by hemostasis device use and gender. J Invasive Cardiol. 2004;16(9):459–464.
  13. Romaguera R, Wakabayashi K, Laynez-Carnicero A, et al. Association between bleeding severity and long-term mortality in patients experiencing vascular complications after percutaneous coronary intervention. Am J Cardiol. 2012;109(1):75–81. doi: 10.1016/j.amjcard.2011.08.007
  14. Sanmartin M, Gomez M, Rumoroso JR, et al. Interruption of blood flow during compression and radial artery occlusion after transradial catheterization. Catheter Cardiovasc Interv. 2007;70(2):185–189. doi: 10.1002/ccd.21058
  15. Pancholy SB. Transradial access in an occluded radial artery: new technique. J Invasive Cardiol. 2007;19(12):541–544.
  16. Spaulding C, Lefevre T, Funck F, et al. Left radial approach for coronary angiography: results of a prospective study. Cathet Cardiovasc Diagn. 1996;39(4):365–370. doi: 10.1002/(SICI)1097-0304(199612)39:4<365::AID-CCD8>3.0.CO;2-B
  17. Sakai H, Ikeda S, Harada T, et al. Limitations of successive transradial approach in the same arm: the Japanese experience. Catheter Cardiovasc Interv. 2001;54(2):204–208. doi: 10.1002/ccd.1268
  18. Saito S, Ikei H, Hosokawa G, Tanaka S. Influence of the ratio between radial artery inner diameter and sheath outer diameter on radial artery flow after transradial coronary intervention. Catheter Cardiovasc Interv. 1999;46(2):173–178. doi: 10.1002/(SICI)1522-726X(199902)46:2<173::AID-CCD12>3.0.CO;2-4
  19. Wakeyama T, Ogawa H, Iida H, et al. Intima-media thickening of the radial artery after transradial intervention. An intravascular ultrasound study. J Am Coll Cardiol. 2003;41(7):1109–1114. doi: 10.1016/s0735-1097(03)00089-5
  20. Yonetsu T, Kakuta T, Lee T, et al. Assessment of acute injuries and chronic intimal thickening of the radial artery after transradial coronary intervention by optical coherence tomography. Eur Heart J. 2010;31(13):1608–1615. doi: 10.1093/eurheartj/ehq102
  21. Kamiya H, Ushijima T, Kanamori T, et al. Use of the radial artery graft after transradial catheterization: is it suitable as a bypass conduit? Ann Thorac Surg. 2003;76(5):1505–1509. doi: 10.1016/s0003-4975(03)01018-x
  22. Kiemeneij F. Prevention and management of radial artery spasm. J Invasive Cardiol. 2006;18(4):159–160.
  23. Coppola J, Patel T, Kwan T, et al. Nitroglycerin, nitroprusside, or both, in preventing radial artery spasm during transradial artery catheterization. J Invasive Cardiol. 2006;18(4):155–158.
  24. Ouadhour A, Sideris G, Smida W, et al. Usefulness of subcutaneous nitrate for radial access. Catheter Cardiovasc Interv. 2008;72(3):343. doi: 10.1002/ccd.21645
  25. Sanmartin M, Cuevas D, Goicolea J, et al. Vascular complications associated with radial artery access for cardiac catheterization. Rev Esp Cardiol. 2004;57(6):581–584. (In Span.) doi: 10.1016/S0300-8932(04)77150-X
  26. Calvino-Santos RA, Vazquez-Rodriguez JM, Salgado-Fernandez J, et al. Management of iatrogenic radial artery perforation. Catheter Cardiovasc Interv. 2004;61(1):74–78. doi: 10.1002/ccd.10698
  27. Gunasekaran S, Cherukupalli R. Radial artery perforation and its management during PCI. J Invasive Cardiol. 2009;21(2):E24–26.
  28. Rigatelli G, Dell'Avvocata F, Ronco F, Doganov A. Successful coronary angioplasty via the radial approach after sealing a radial perforation. JACC Cardiovasc Interv. 2009;2(11):1158–1159. doi: 10.1016/j.jcin.2009.05.026
  29. Tizon-Marcos H, Barbeau GR. Incidence of compartment syndrome of the arm in a large series of transradial approach for coronary procedures. J Interv Cardiol. 2008;21(5):380–384. doi: 10.1111/j.1540-8183.2008.00361.x
  30. Kang SS, Labropoulos N, Mansour MA, et al. Expanded indications for ultrasound-guided thrombin injection of pseudoaneurysms. J Vasc Surg. 2000;31(2):289–298. doi: 10.1016/s0741-5214(00)90160-5
  31. Liou M, Tung F, Kanei Y, Kwan T. Treatment of radial artery pseudoaneurysm using a novel compression device. J Invasive Cardiol. 2010;22:293–295.
  32. Kanei Y, Kwan T, Nakra NC, et al. Transradial cardiac catheterization: A Review of Access Site Complications. Catheter Cardiovasc Interv. 2011;78(6):840–846. doi: 10.1002/ccd.22978
  33. Levine GN, Bates ER, Blankenship JC, et al. 2011 ACCF/AHA/SCAI Guideline for Percutaneous Coronary Intervention. A report of the American College of Cardiology Foundation/American Heart Association Task Force on Practice Guidelines and the Society for Cardiovascular Angiography and Interventions. J Am Coll Cardiol. 2011;58(24):e44–122. doi: 10.1016/j.jacc.2011.08.007
  34. Sherev DA, Shaw RE, Brent BN. Angiographic predictors of femoral access site complications: implication for planned percutaneous coronary intervention. Catheter Cardiovasc Interv. 2005;65(2):196–202. doi: 10.1002/ccd.20354
  35. Ben-Dor I, Sharma A, Rogers T, et al. Micropuncture technique for femoral access is associated with lower vascular complications compared to standard needle. Catheter Cardiovasc Interv. 2021;97(70):1379–1385. doi: 10.1002/ccd.29330
  36. Larena-Avellaneda A, Kölbel T, Carpenter SW, et al. Iatrogene Verletzungen an den Zugangsgefäßen für intravaskuläre Prozeduren. Notfall + Rettungsmedizin. 2017;20:305–314. doi: 10.1007/s10049-017-0287-5

补充文件

附件文件
动作
1. JATS XML
2. Fig. 1. Topography of the femoral artery (from [36])

下载 (210KB)
3. Fig. 2. Massive hematoma in the right inguinal region and thigh after percutaneous coronary intervention (author’s case)

下载 (165KB)
4. Fig. 3. Massive puncture site hematoma extending to the proximal femur; a ― radiological image; b ― rapid soft tissue necrosis due to hematoma pressure from the inside; c ― clinical presentation 8 days after hematoma evacuation and revision of the puncture site (author’s case)

下载 (527KB)
5. Fig. 4. Giant lymphocele (> 2.5 L) after evacuation of a retroperitoneal hematoma (author’s case)

下载 (213KB)
6. Fig. 5. Post-intervention arteriovenous fistula. The arrow indicates contrasting of the femoral vein (author’s case)

下载 (228KB)

版权所有 © Kimkov A., 2022

Creative Commons License
此作品已接受知识共享署名-非商业性使用-禁止演绎 4.0国际许可协议的许可。

Согласие на обработку персональных данных с помощью сервиса «Яндекс.Метрика»

1. Я (далее – «Пользователь» или «Субъект персональных данных»), осуществляя использование сайта https://journals.rcsi.science/ (далее – «Сайт»), подтверждая свою полную дееспособность даю согласие на обработку персональных данных с использованием средств автоматизации Оператору - федеральному государственному бюджетному учреждению «Российский центр научной информации» (РЦНИ), далее – «Оператор», расположенному по адресу: 119991, г. Москва, Ленинский просп., д.32А, со следующими условиями.

2. Категории обрабатываемых данных: файлы «cookies» (куки-файлы). Файлы «cookie» – это небольшой текстовый файл, который веб-сервер может хранить в браузере Пользователя. Данные файлы веб-сервер загружает на устройство Пользователя при посещении им Сайта. При каждом следующем посещении Пользователем Сайта «cookie» файлы отправляются на Сайт Оператора. Данные файлы позволяют Сайту распознавать устройство Пользователя. Содержимое такого файла может как относиться, так и не относиться к персональным данным, в зависимости от того, содержит ли такой файл персональные данные или содержит обезличенные технические данные.

3. Цель обработки персональных данных: анализ пользовательской активности с помощью сервиса «Яндекс.Метрика».

4. Категории субъектов персональных данных: все Пользователи Сайта, которые дали согласие на обработку файлов «cookie».

5. Способы обработки: сбор, запись, систематизация, накопление, хранение, уточнение (обновление, изменение), извлечение, использование, передача (доступ, предоставление), блокирование, удаление, уничтожение персональных данных.

6. Срок обработки и хранения: до получения от Субъекта персональных данных требования о прекращении обработки/отзыва согласия.

7. Способ отзыва: заявление об отзыве в письменном виде путём его направления на адрес электронной почты Оператора: info@rcsi.science или путем письменного обращения по юридическому адресу: 119991, г. Москва, Ленинский просп., д.32А

8. Субъект персональных данных вправе запретить своему оборудованию прием этих данных или ограничить прием этих данных. При отказе от получения таких данных или при ограничении приема данных некоторые функции Сайта могут работать некорректно. Субъект персональных данных обязуется сам настроить свое оборудование таким способом, чтобы оно обеспечивало адекватный его желаниям режим работы и уровень защиты данных файлов «cookie», Оператор не предоставляет технологических и правовых консультаций на темы подобного характера.

9. Порядок уничтожения персональных данных при достижении цели их обработки или при наступлении иных законных оснований определяется Оператором в соответствии с законодательством Российской Федерации.

10. Я согласен/согласна квалифицировать в качестве своей простой электронной подписи под настоящим Согласием и под Политикой обработки персональных данных выполнение мною следующего действия на сайте: https://journals.rcsi.science/ нажатие мною на интерфейсе с текстом: «Сайт использует сервис «Яндекс.Метрика» (который использует файлы «cookie») на элемент с текстом «Принять и продолжить».