Digital stethoscope: a new era of auscultation

Cover Image

Cite item

Abstract

The article reviews modern electronic and digital stethoscopes. The publications of the last 10 years were analyzed using eLIBRARY.ru, PubMed, Google Scholar with “аускультация” (“auscultation”), “электронный стетоскоп” (“electronic stethoscope”), “цифровой стетоскоп” (“digital stethoscope”), and “телемедицина” (“telemedicine”) keywords. New ways to auscultate using digital stethoscopes were considered. Products from the most popular manufacturers were briefly characterized. Improved functionality and versatility of a digital stethoscope (ability to evaluate heart, lung, bowel, and other organ sounds), noise reduction and sound filtering make digital stethoscopes an even more attractive tool. If these challenges are met, a digital stethoscope will undoubtedly become an indispensable tool in the diagnosis, monitoring and treatment of diseases and in patient self monitoring. Telemonitoring of patients with cardiovascular and respiratory diseases is a promising area of application for modern models of digital stethoscopes. Auscultation is especially important to evaluate changes during long term follow up, for early detection of complications and decompensated chronic non infectious diseases such as chronic obstructive pulmonary disease, asthma, myocardial infarction, etc.

About the authors

Andrey A. Garanin

Samara State Medical University

Author for correspondence.
Email: a.a.garanin@samsmu.ru
ORCID iD: 0000-0001-6665-1533
SPIN-code: 9976-3085
Scopus Author ID: 56700078400

MD, Cand. Sci. (Medicine)

Russian Federation, Samara

Olesya Y. Aydumova

Samara State Medical University

Email: o.yu.ajdumova@samsmu.ru
ORCID iD: 0000-0001-5673-7958
SPIN-code: 6330-2186

MD

Russian Federation, Samara

Anatoly O. Rubanenko

Samara State Medical University

Email: a.o.rubanenko@samsmu.ru
ORCID iD: 0000-0002-3996-4689
SPIN-code: 6947-1028

кафедра пропедевтической терапии с курсом кардиологии, доцент, к.м.н.

Russian Federation, Samara

Elena G. Bibikova

Samara State Medical University

Email: e.g.bibikova@samsmu.ru
ORCID iD: 0009-0005-9392-1101
SPIN-code: 1578-1620
Russian Federation, Samara

References

  1. Swarup S, Mararyus AN. Digital stethoscope: technology update. Med Devices (Auckl). 2018;11:29–36. doi: 10.2147/MDER.S135882
  2. Landge K, Kidambi BR, Singal A, Basha A. Electronic stethoscopes: brief review of clinical utility, evidence, and future implications. Journal of the Practice of Cardiovascular Sciences. 2018;4(2):65–68. doi: 10.4103/jpcs.jpcs_47_18
  3. Grenier M. C, Gagnon K, Genest J, et al. Clinical comparison of acoustic and electronic stethoscopes and design of a new electronic stethoscope. Am J Cardiol. 1998;81(5):653–656. doi: 10.1016/s0002-9149(97)00977-6
  4. Nussbaumer M, Agarwal A. Stethscope acoustics. J Sound Vib. 2022;539:1171–1194. doi: 10.1016/j.jsv.2022.117194
  5. Tavel ME. Cardiac auscultation: a glorious past — and it does have a future! Circulation. 2006;113(9):1255–1259. doi: 10.1161/CIRCULATIONAHA.105.591149.
  6. Nowak LJ, Nowak KM. Sound differences between electronic and acoustic stethoscopes. Biomed Eng Online. 2018;17(1):104. doi: 10.1186/s12938-018-0540-2
  7. Kudryavtseva ES, Akhmetzyanova NM. Electronic stethoscope: new gadget for dianostics and self diagnostics. Arkhitektura zdorov’ya. 2020(1):44–49. (In Russ.) EDN: GUSAON
  8. Leng S, Tan RS, Chai KT, et al. The electronic stethoscope. Biomed Eng Online. 2015;14(1):66. doi: 10.1186/s12938-015-0056-y
  9. Grundlehner B, Buxi D. Methods to characterize sensors for capturing body sounds. In: International Conference on Body Sensor Networks (BSN); 2011 May 23–25; Dallas, TX, USA. doi: 10.1109/BSN.2011.22
  10. Kevin TCC, Han D, Ravinder PS, et al. 118-db dynamic range, continuous time, opened loop capacitance to voltage converter readout for capacitive MEMS accelerometer. In: IEEE Asian Solid State Circuits Conference; 2010 Nov 08–10; Beijing, China. doi: 10.1109/ASSCC.2010.5716626
  11. Cain PA, Ahroon WA, Greenburg D. An Assessment of acoustic and electronic stethoscope performance in the UH-60 noise environment. U.S. Army Aeromedical Research Laboratory, Aircrew Protection Division; 2002 Aug. Report No.: 2002–20. Program element No.: 622787, project No.: 878.
  12. Thinklabs One [Internet]. [cited 20 May 2024]. Available from: https://www.thinklabs.com/stethoscopes
  13. The 3M Littmann CORE Digital Stethoscope [Internet]. [cited 20 May 2024]. Available from: https://www.littmann.com/3M/en_US/littmannstethoscopes/advantages/coredigitalstethoscope/
  14. Silverman B, Balk M. Digital stethoscope — improved auscultation at the bedside. Am J Cardiol. 2019;123(6):984–985. doi: 10.1016/j.amjcard.2018.12.022
  15. Azimpour F, Caldwell E, Tawfik P, et al. Audible coronary artery stenosis. Am J Med. 2016;129(5):515–521. doi: 10.1016/j.amjmed.2016.01.015
  16. Thomas JL, Winther S, Wilson RF, Bøttcher M. A novel approach to diagnosing coronary artery disease: acoustic detection of coronary turbulence. Int J Cardiovasc Imaging. 2017;33(1):129–136. doi: 10.1007/s10554-016-0970-5
  17. Jain A, Sahu R, Gaumnitz T, et al. Development and validation of a low cost electronic stethoscope: DIY digital stethoscope. BMJ Innovations. 2021;7:609–613. doi: 10.1136/bmjinnov-2021-000715
  18. Takashina T, Shimizu M, Muratake T, Mayuzumi S. New stethoscope with extensible diaphragm. Circ J. 2016;80(9):2047–2049. doi: 10.1253/circj.CJ-16-0193
  19. Legget ME, Toh M, Meintjes A, et al. Digital devices for teaching cardiac auscultation — A randomized pilot study. Med Educ Online. 2018;23(1):1524688. doi: 10.1080/10872981.2018.1524688
  20. Gurung A, Scafford CG, Tielsch JM, et al. Computerized lung sound analysis as diagnostic aid for the detection of abnormal lung sounds: a systematic review and meta analysis. Respir Med. 2011;105(9):1396–1403. doi: 10.1016/j.rmed.2011.05.007
  21. Kaddoura T, Vadlamudi K, Kumar S, et al. Acoustic diagnosis of pulmonary hypertension: automated speed recognition inspired classification algorithm outperforms physicians. Sci Rep. 2016;6:331382. doi: 10.1038/srep33182
  22. Seah JJ, Zhao J, Wang DY, Lee HP. Review on the advancements of stethoscope types in chest auscultation. Diagnostics. 2023;13(9):1545. doi: 10.3390/diagnostics13091545
  23. Stetoskopy.ru [Internet]. [cited 14 April 2024]. Available from: http://stetoskopy.ru/shop/3mlittmann/3200_BK_27.html/
  24. Mamorita N, Arisaka N, Isonaka R, et al. Development of Smartphone App for visualizing heart sounds and murmurs. Cardiology. 2017;137(3):193–200. doi: 10.1159/000466683
  25. Stethee Pro [Internet]. [cited 20 May 2024]. Available from: https://m3dicine.com/#deeper_level
  26. Dealmed [Internet]. [cited 20 May 2024]. Available from: https://www.dealmed.ru/stetoskop_elektronniy_ekuore_pro.html
  27. StethoMe [Internet]. [cited 20 May 2024]. Available from: https://www.stethome.com/engb/
  28. EverCare [Internet]. [cited 20 May 2024]. Available from: https://evercare.ru/cadence
  29. Ekoscope [Internet]. [cited 20 May 2024]. Available from: https://ekoscope.com/ekoscope
  30. LungPass [Internet]. [cited 20 May 2024]. Available from: https://cetez.ru/lungpass/
  31. Laeneco Smart stethoscope [Internet]. [cited 20 May 2024]. Available from: https://laenecocom.tmweb.ru/
  32. Honkoop P, Usmani O, Bonini M. The current and future role of technology in respiratory care. PulmTher. 2022;8(2):167–179. doi: 10.1007/s41030-022-00191-y

Supplementary files

Supplementary Files
Action
1. JATS XML
2. Fig. 1. Appearance of the most popular electronic stethoscopes on the market: a — stethoscope ZM Littmann 3200 (USA) http://stetoskopy.ru/shop/3m-littmann/3200_BK_27.html ; b — M3DICINE Stethee Pro™ stethoscope (Australia) https://m3dicine.com/#deeper_level ; Thinklabs One™ c — stethoscope (USA) https://www.thinklabs.com/stethoscopes ; d — eKuore Pro™ cardiological stethoscope (Spain) https://www.deal-med.ru/stetoskop_elektronniy_ekuore_pro.html ; StethoMe™ e — stethoscope (Poland) https://www.stethome.com/en-gb /; f — sensors of the CADence™ Heart Disease Diagnostic system (USA) https://evercare.ru/cadence ; g — stethoscope with electrocardiogram recording capability Ekoscope™ (USA) https://ekoscope.com/ekoscope ; Healthy Networks Lung Passport™ h — stethoscope (Belarus) https://cetez.ru/lungpass /; i — Laeneco™ stethoscope (Russia) https://laenecocom.tmweb.ru/.

Download (174KB)

Copyright (c) 2024 Eco-Vector

Creative Commons License
This work is licensed under a Creative Commons Attribution-NonCommercial-NoDerivatives 4.0 International License.

Согласие на обработку персональных данных с помощью сервиса «Яндекс.Метрика»

1. Я (далее – «Пользователь» или «Субъект персональных данных»), осуществляя использование сайта https://journals.rcsi.science/ (далее – «Сайт»), подтверждая свою полную дееспособность даю согласие на обработку персональных данных с использованием средств автоматизации Оператору - федеральному государственному бюджетному учреждению «Российский центр научной информации» (РЦНИ), далее – «Оператор», расположенному по адресу: 119991, г. Москва, Ленинский просп., д.32А, со следующими условиями.

2. Категории обрабатываемых данных: файлы «cookies» (куки-файлы). Файлы «cookie» – это небольшой текстовый файл, который веб-сервер может хранить в браузере Пользователя. Данные файлы веб-сервер загружает на устройство Пользователя при посещении им Сайта. При каждом следующем посещении Пользователем Сайта «cookie» файлы отправляются на Сайт Оператора. Данные файлы позволяют Сайту распознавать устройство Пользователя. Содержимое такого файла может как относиться, так и не относиться к персональным данным, в зависимости от того, содержит ли такой файл персональные данные или содержит обезличенные технические данные.

3. Цель обработки персональных данных: анализ пользовательской активности с помощью сервиса «Яндекс.Метрика».

4. Категории субъектов персональных данных: все Пользователи Сайта, которые дали согласие на обработку файлов «cookie».

5. Способы обработки: сбор, запись, систематизация, накопление, хранение, уточнение (обновление, изменение), извлечение, использование, передача (доступ, предоставление), блокирование, удаление, уничтожение персональных данных.

6. Срок обработки и хранения: до получения от Субъекта персональных данных требования о прекращении обработки/отзыва согласия.

7. Способ отзыва: заявление об отзыве в письменном виде путём его направления на адрес электронной почты Оператора: info@rcsi.science или путем письменного обращения по юридическому адресу: 119991, г. Москва, Ленинский просп., д.32А

8. Субъект персональных данных вправе запретить своему оборудованию прием этих данных или ограничить прием этих данных. При отказе от получения таких данных или при ограничении приема данных некоторые функции Сайта могут работать некорректно. Субъект персональных данных обязуется сам настроить свое оборудование таким способом, чтобы оно обеспечивало адекватный его желаниям режим работы и уровень защиты данных файлов «cookie», Оператор не предоставляет технологических и правовых консультаций на темы подобного характера.

9. Порядок уничтожения персональных данных при достижении цели их обработки или при наступлении иных законных оснований определяется Оператором в соответствии с законодательством Российской Федерации.

10. Я согласен/согласна квалифицировать в качестве своей простой электронной подписи под настоящим Согласием и под Политикой обработки персональных данных выполнение мною следующего действия на сайте: https://journals.rcsi.science/ нажатие мною на интерфейсе с текстом: «Сайт использует сервис «Яндекс.Метрика» (который использует файлы «cookie») на элемент с текстом «Принять и продолжить».