Evaluating the Microhardness of Samples Based on Binder VST-1210 Cured under Various Conditions as a Method of Testing


Citar

Texto integral

Acesso aberto Acesso aberto
Acesso é fechado Acesso está concedido
Acesso é fechado Somente assinantes

Resumo

Using a PMT-3M microhardness tester, the microhardness values depending on the distance of the spot of measurement from the frontal plane of the sample to its middle part are determined on the transverse sections of samples of binder VST-1210 hardened under various conditions. It is established that the microhardness value of a plastic depends on the conditions of its curing and also on the spot at which the measurement is carried out—the closer the sample core to the spot of measurement, the higher the microhardness value. The performed sclerometric tests have shown that the width of the groove trace also increases from the middle to the frontal plane of the sample.

Sobre autores

E. Veshkin

Ul’yanovsk Science and Technology Center, All-Russian Institute of Aviation Materials

Autor responsável pela correspondência
Email: untcviam@viam.ru
Rússia, Ul’yanovsk

V. Postnov

Ul’yanovsk Science and Technology Center, All-Russian Institute of Aviation Materials

Email: untcviam@viam.ru
Rússia, Ul’yanovsk

V. Semenychev

Ul’yanovsk Science and Technology Center, All-Russian Institute of Aviation Materials

Email: untcviam@viam.ru
Rússia, Ul’yanovsk

Arquivos suplementares

Arquivos suplementares
Ação
1. JATS XML

Declaração de direitos autorais © Pleiades Publishing, Ltd., 2019