Tactile and pain sensitivity of the oral mucosa has been the subject of study of a number of researchers. However, the numerical values of the thresholds of the excitation of the baro - and mechanoreceptors of the mucosa of the oral cavity not sufficiently detailed in the literature, experimental data is highly scattered, often presented without specifying the method of measurement or sections of the jaws, which were received. However, the authors note the unequal sensitivity of the mucous membrane in its different areas and its dependence on the presence or absence of a number of chronic diseases. Systematic study on the diagnosis of sensitivity associated with dental prostheses of the prosthetic bed tissues to pressure, virtually no. In this report the authors made some attempt to rectify this gap. It shows the numerical values of thresholds of pain sensitivity of the mucous membrane of the oral cavity of humans and animals by mechanical action on the basis of literary data and results of numerical analysis of the mathematical model “obturator maxillary prosthesis - mucosa the edges of the defect of the upper jaw”. The average value of the lower threshold of pain sensitivity was 20,72 g/m2 according to the data of different authors, and the upper limit was 63,82 g/m2.

About the authors

A. S Arutyunov

A.I. Evdokimov Moscow State Medical Stomatological University

127473, Moscow, Russia

S. S Pertsov

A.I. Evdokimov Moscow State Medical Stomatological University

127473, Moscow, Russia

Sergey Aleksandrovich Muslov

A.I. Evdokimov Moscow State Medical Stomatological University

Email: muslov@mail.ru
Dr. Biol. Sci., Prof. 127473, Moscow, Russia

Z. L Shanidze

A.I. Evdokimov Moscow State Medical Stomatological University

127473, Moscow, Russia

References

  1. Арутюнов А.С., Шанидзе З.Л., Муслов С.А. Имитационное моделирование системы «обтуратор челюстного протеза -слизистая оболочка края дефекта верхней челюсти». Современные проблемы науки и образования. 2016; 5: URL: http:// www.science-ducation.ru/pdf/2016/5/25190.pdf (дата обращения: 23.09.2016).
  2. Арутюнов С.Д., Колесников Л.Л., Дегтярев В.П., Лебеденко И.Ю. Анатомия, физиология и биомеханика зубочелюстной системы. М.: Гэотар-Медиа; 2017.
  3. Болевая чувствительность [Электронный ресурс]. URL: http:// medcentr-tyumen.ru/bolevaya-chuvstvitelnost.html.
  4. Диасамидзе Э.Д. Дентальная плексалгия, как фактор дезадаптации к съемным протезам. Современная медицина: актуальные вопросы: сб. по матер. XX международная науч.-практ. конф. Новосибирск: СибАК; 2013.
  5. Еганова Т.Д., Бусыгин А.Т. Пороговая компрессия слизистой оболочки протезного ложа. Ташкент: Медицина; 1973.
  6. Иорданишвили А.К., Бельских О.А., Тишков Д.С., Карев Ф.А., Музыкин Н.И. Особенности функционирования слизистой оболочки полости рта и языка при хронических заболеваниях почек, кишечника и эндокринной патологии. Курский научный-практический вестник «Человек и его здоровье». 2015; 4: 30-4.
  7. Курляндский В.Ю. и др. Методы исследования в ортопедической стоматологии. Ташкент: Медицина; 1973.
  8. Маркелова Е.В., Красников В.Е. Патофизиология челюстнолицевой области: учебное пособие в 2 частях. ч. 2. Владивосток; 2005:
  9. Сенсорная функция полости рта и её особенности [Электронный ресурс]. URL: http://www.nsmu.ru/student/faculty/department/ physiology/learn_proc/Prof_ST_Anal.pdf.
  10. Chen J., Ahmad R., Li W., Swain M., Li Q. Biomechanics of oral mucosa. J. R. Soc. Interface. 2015; 12 (109): DOI: 10.1098/ rsif.2015.0325
  11. Cooper B. et al. Parallels between properties of high-threshold mechanoreceptors of the goat oral mucosa and human pain report. Exp. Brain Res. 1993; 94(2): 323-35.
  12. Massarelli O. et al. The Folded Tunnelized-Facial Artery Myomu-cosal Island Flap: A New Technique for Total Soft Palate Reconstruction. J. Oral Maxillofac Surg. 2013; 71: 192-8,
  13. Davenpor J.C. Pressure-pain thresholds in oral cavity in man. Arch. Oral Biol. 1969; 14: 1267-74. (doi: 10.1016/0003-9969-(69)90199-X).
  14. McMillan A.S. Pain-pressure threshold in human gingivae. J. Orofacial Pain. 1995; 9: 44-50.
  15. Ogawa T., Ogimoto T., Sumiyoshi K., Koyano K. Pressure-pain threshold of oral mucosa and its region-specific modulation by preloading. J. Oral Rehabil. 2003; 30: 1062-9. (doi: 10.1046/j.1365-2842. 2003.01183.x).
  16. Ogawa T., Tanaka M., Ogimoto T., Okushi N., Koyano K., Takeuchi K. Mapping, profiling and clustering of pressure pain threshold (PPT) in edentulous oral mucosa. J. Dent. 2004; 32: 219-28. (doi: 10.1016/j.jdent.2003.11.001).
  17. Ogimoto T., Ogawa T., Sumiyoshi K., Matsuka Y., Koyano K. Pressure-pain threshold determination in the oral mucosa: validity and reliability. J. Oral Rehabil. 2002; 29: 620-6. (doi:10. 1046/j.1365-2842.2002. 00874.x).
  18. Okayasu I., Komiyama O., Yoshida N., Oi K., De Laat A. Effects of chewing efforts on the sensory and pain thresholds in human facial skin: A pilot study. Arch. Oral Biol. 2012; 57(9): 1251-5.
  19. S. R. Dowgan T. de Siqueira, Teixeira M.J., de Siqueira J.T.T. Orofacial pain and sensory characteristics of chronic patients compared with controls. Oral Med. 2013; 115(6): e37-e45.
  20. Suzuki Y., Katoh M., Sato J., Morokuma M., Hosoi M.A., Ohkubo C. Pressure pain threshold of mucosa after tooth extraction under removable denture bases. Eur. J. Prosthodont. Restorative Dent. 2011; 19: 184-6.
  21. Svensson P., Bjerring P., Arendt-Nielsen L. Kaaber S. Variability of argon laser-induced sensory and pain thresholds on human oral mucosa and skin. Anesthesia Progress. 1991; 38(3): 79-83.
  22. Tanaka M., Ogimoto T., Koyano K., Ogawa T. Denture wearing and strong bite force reduce pressure pain threshold of edentulous oral mucosa. J. Oral Rehabil. 2004; 31: 873-8. (doi: 10.1111/j.1365-2842.2004.01321.x).

Copyright (c) 2018 Eco-Vector


 


This website uses cookies

You consent to our cookies if you continue to use our website.

About Cookies