Development and Study of the Start-Up Sequence for E-240-13.8-560 Solid-Fuel-Fired Boiler by the Zio Company


Citar

Texto integral

Acesso aberto Acesso aberto
Acesso é fechado Acesso está concedido
Acesso é fechado Somente assinantes

Resumo

The results of the development and study of the start-up sequence for an E-240-13.8-560KT steam boiler are presented. Criteria of reliable operation of boiler components during start-up are proposed. The change in the main operating conditions of the boiler during start-up is described. The use of emergency start-up injection is justified. The effect of the wall thickness of the drum on the start-up of the boiler is analyzed.

Sobre autores

K. Pleshanov

JSC “Machine-Building Factory of Podolsk,”; National Research University “Moscow Power Engineering Institute,”

Autor responsável pela correspondência
Email: PleshanovKA@mpei.ru
Rússia, Podolsk; Moscow

K. Sterkhov

JSC “Machine-Building Factory of Podolsk,”; National Research University “Moscow Power Engineering Institute,”

Email: PleshanovKA@mpei.ru
Rússia, Podolsk; Moscow

V. Knyaz’kov

JSC “Machine-Building Factory of Podolsk,”

Email: PleshanovKA@mpei.ru
Rússia, Podolsk

A. Kvrivishvili

JSC “Machine-Building Factory of Podolsk,”

Email: PleshanovKA@mpei.ru
Rússia, Podolsk

Arquivos suplementares

Arquivos suplementares
Ação
1. JATS XML

Declaração de direitos autorais © Springer Science+Business Media, LLC, part of Springer Nature, 2018