Draft Tubes of Water Turbines in Underground and Semi-Underground Powerhouses


Cite item

Full Text

Open Access Open Access
Restricted Access Access granted
Restricted Access Subscription Access

Abstract

The effect of the centerline radius, bend angle, and diffuser length of high draft tubes in underground and semi-underground powerhouses on head losses is studied analytically. It is established that the dependence of the head losses on the diffuser length does not depend on the capacity, flow rate, and runner diameter of the water turbine; therefore, the diffuser length should be consistent with the construction conditions, but no greater than 35 – 40 m. The centerline radius r0 of the elbow increases with its bend angle α.

About the authors

I. E. Mikhailov

Moscow State University of Civil Engineering

Author for correspondence.
Email: orexov-gv@mail.ru
Russian Federation, Moscow

Supplementary files

Supplementary Files
Action
1. JATS XML

Copyright (c) 2018 Springer Science+Business Media, LLC, part of Springer Nature