Draft Tubes of Water Turbines in Underground and Semi-Underground Powerhouses
- Авторлар: Mikhailov I.E.1
-
Мекемелер:
- Moscow State University of Civil Engineering
- Шығарылым: Том 52, № 2 (2018)
- Беттер: 185-190
- Бөлім: Article
- URL: https://journals.rcsi.science/1570-145X/article/view/246134
- DOI: https://doi.org/10.1007/s10749-018-0930-4
- ID: 246134
Дәйексөз келтіру
Аннотация
The effect of the centerline radius, bend angle, and diffuser length of high draft tubes in underground and semi-underground powerhouses on head losses is studied analytically. It is established that the dependence of the head losses on the diffuser length does not depend on the capacity, flow rate, and runner diameter of the water turbine; therefore, the diffuser length should be consistent with the construction conditions, but no greater than 35 – 40 m. The centerline radius r0 of the elbow increases with its bend angle α.
Негізгі сөздер
Авторлар туралы
I. Mikhailov
Moscow State University of Civil Engineering
Хат алмасуға жауапты Автор.
Email: orexov-gv@mail.ru
Ресей, Moscow
Қосымша файлдар