Heat transfer at a laminar free convection and separated flow past a rib in a vertical channel with isothermal walls


如何引用文章

全文:

开放存取 开放存取
受限制的访问 ##reader.subscriptionAccessGranted##
受限制的访问 订阅存取

详细

The results of numerical computations of a free laminar convection and heat transfer between two parallel isothermal plates in the presence of a single rib on the channel surface are presented. The investigations have been conducted for a channel with the aspect ratio AR = L/w = 10, where L is the channel height, and w is the distance between the plates. An infinitely thin adiabatic rib was located on one of the channel walls in the middle of its height. The relative rib height l/w was varied in the range 0÷0.8. The wall temperature was higher than the ambient temperature, and the Rayleigh number was varied in the range Ra = 102÷105. The main attention has been paid to the study of the influence of the rib height and the Rayleigh number on local and integral heat transfer and the Reynolds number in the channel (the convective thrust). A fundamental difference in the heat transfer over the channel height has been shown on the ribbed wall and on a smooth surface. The computational results have been compared with the case of a symmetric distribution of the ribs on the both walls with the integral height equal to a single rib.

作者简介

V. Terekhov

Kutateladze Institute of Thermophysics SB RAS; Novosibirsk State Technical University

编辑信件的主要联系方式.
Email: terekhov@itp.nsc.ru
俄罗斯联邦, Novosibirsk; Novosibirsk

A. Ekaid

University of Technology

Email: terekhov@itp.nsc.ru
伊拉克, Baghdad

K. Yassin

Novosibirsk State Technical University; Northern Technical University

Email: terekhov@itp.nsc.ru
俄罗斯联邦, Novosibirsk; Kirkuk

补充文件

附件文件
动作
1. JATS XML

版权所有 © Pleiades Publishing, Ltd., 2017