The results of experimental studies on the structure of the temperature field in the tube cross section at the flow of liquid-metal coolant in a T-shaped mixer are presented. Experiments were carried out using the Rose alloy as the working fluid. To determine temperature distribution on the test section wall, infrared thermography was used; to determine temperature distribution in the channel cross section, a mobile thermocouple was used. Considerable temperature maldistribution in the mixing zone of liquid flows with different temperatures on the tube wall and in the coolant melt is shown.