Comparative effectiveness of infrared heat sources for mounting and dismounting electronic modules


Cite item

Full Text

Open Access Open Access
Restricted Access Access granted
Restricted Access Subscription Access

Abstract

efficiency of short- and medium-wave infrared (IR) heat sources used to mount and dismount electronic modules is assessed. The analysis of the models of thermal fields shows that for KGM 30/300 halogen IR lamps, the heating nonuniformity for a printed circuit board is 45–55°С, and for the casings of electronic components, the temperature varies from 90 to 100°С. For an Elstein SHTS/4 ceramic IR heater, the heating nonuniformity for a printed circuit board is 8–13°С, the temperature of SMD component casings differs from temperature of the the printed circuit board: in BGA by 28–32°С, in QFP by 24–26°С, and in SMD by 5–20°С. The application of medium-wave ceramic infrared sources makes it possible to attain a higher heating uniformity in the working area and ensure an optimal temperature profile when mounting and dismounting surface-mounted electronic components.

About the authors

V. L. Lanin

Belarusian State University of Informatics and Radioelectronics

Author for correspondence.
Email: vlanin@bsuir.by
Belarus, Minsk, 220013

A. I. Lappo

Belarusian State University of Informatics and Radioelectronics

Email: vlanin@bsuir.by
Belarus, Minsk, 220013

Supplementary files

Supplementary Files
Action
1. JATS XML

Copyright (c) 2017 Allerton Press, Inc.