Application of a system with distributed architecture for information acquisition and processing in tasks of active–adaptive voltage control in distribution electric grids
- Authors: Aleshin S.V.1,2, Vanin A.S.2, Nasyrov R.R.2, Novikov D.O.3, Tul’skii V.N.2
-
Affiliations:
- Technical Automation Department
- Department of Power Electrical Systems
- Promising Projects Department
- Issue: Vol 87, No 8 (2016)
- Pages: 446-451
- Section: Article
- URL: https://journals.rcsi.science/1068-3712/article/view/229554
- DOI: https://doi.org/10.3103/S1068371216080022
- ID: 229554
Cite item
Abstract
An active–adaptive control system for power grids with distributed architecture of data acquisition and processing is considered. The advantages of the proposed control principle are compared with commonly used methods. A domestic apparatus—a programmable recording bay controller (PRBC)—is described. This hardware was designed to measure the basic electrical parameters and create distributed systems for data acquisition and processing. The procedure is considered of supervisory control and data acquisition (SCADA) by the SONATA system based on a multicore distributed architecture having high reliability and supporting a rigid real-time mode. A full-function full-scale model of active–adaptive voltage control system (AAVC) was set up using proposed software and hardware. The AAVC makes it possible to use the results of calculating–measuring procedures to select a corresponding on-load tap-changer (OLTC) on the actual voltage levels in the nodes of distribution grid. This approach to centralized voltage control in distribution grids makes it possible to ensure the required level of voltage in the greatest possible number of power consumers owing to prediction of voltage change. The effect of emergencies (random failure of control equipment) during the operation of an active–adaptive voltage control system is analyzed. A qualitative evaluation of the effect of faults on regulation quality and choice of OLTC connection is carried out. It is shown that, for undisturbed operation of an active–adaptive voltage control system, additional diagnostic tools, backup, and data loss compensation are needed.
About the authors
S. V. Aleshin
Technical Automation Department; Department of Power Electrical Systems
Author for correspondence.
Email: journal-elektrotechnika@mail.ru
Russian Federation, pr. Akademika Semenova 9, Chernogolovka, Moscow oblast, 142432; ul. Krasnokazarmennaya 17, Moscow, 111250
A. S. Vanin
Department of Power Electrical Systems
Email: journal-elektrotechnika@mail.ru
Russian Federation, ul. Krasnokazarmennaya 17, Moscow, 111250
R. R. Nasyrov
Department of Power Electrical Systems
Email: journal-elektrotechnika@mail.ru
Russian Federation, ul. Krasnokazarmennaya 17, Moscow, 111250
D. O. Novikov
Promising Projects Department
Email: journal-elektrotechnika@mail.ru
Russian Federation, pr. Akademika Semenova 9, Chernogolovka, Moscow oblast, 142432
V. N. Tul’skii
Department of Power Electrical Systems
Email: journal-elektrotechnika@mail.ru
Russian Federation, ul. Krasnokazarmennaya 17, Moscow, 111250
Supplementary files
