Hydraulic and Thermal Regulation of Coke Batteries with Unidirectional Gas Input and Product Output


Cite item

Full Text

Open Access Open Access
Restricted Access Access granted
Restricted Access Subscription Access

Abstract

The problems arising in the operation of coke battery 3 at Rourkela Steel Plant (India) are considered. The design of coke battery 3 is described. It has an Otto system; the capacity of a single coking chamber is 21.6 m3. Hybrid heating is employed, and heating gas is supplied to the bottom of the chamber. A method is proposed for hydraulic regulation of the coke battery with unidirectional heating-gas input and product output.