Hydraulic and Thermal Regulation of Coke Batteries with Unidirectional Gas Input and Product Output


Citar

Texto integral

Acesso aberto Acesso aberto
Acesso é fechado Acesso está concedido
Acesso é fechado Somente assinantes

Resumo

The problems arising in the operation of coke battery 3 at Rourkela Steel Plant (India) are considered. The design of coke battery 3 is described. It has an Otto system; the capacity of a single coking chamber is 21.6 m3. Hybrid heating is employed, and heating gas is supplied to the bottom of the chamber. A method is proposed for hydraulic regulation of the coke battery with unidirectional heating-gas input and product output.