Theoretical justification of the possibility of cryocooling of a solid target at irradiation with proton beam from cyclotron C18


Citar

Texto integral

Acesso aberto Acesso aberto
Acesso é fechado Acesso está concedido
Acesso é fechado Somente assinantes

Resumo

The thermal physics processes of solid target cooling at proton beam irradiation in С18 cyclotron were calculated. The calculations were made with the help of finite-elements method using ANSYS program for beams with nonuniform density of particle distribution in the beam profile. It was shown that the radiation efficiency and conditions of target cooling essentially depend on distributions of particles in the beam and on efficient size of beam. A principal possibility of the cryocooling of target is shown that would essentially increase the radiation efficiency and the yield of final product–the medical isotope 99mTc. The developed calculation method may be of use also for other processes of target irradiation with charged particle beams.

Sobre autores

G. Harutyunyan

Alikhanyan National Scientific Laboratory

Autor responsável pela correspondência
Email: gevharut@mail.yerphi.am
Armênia, Yerevan

Arquivos suplementares

Arquivos suplementares
Ação
1. JATS XML

Declaração de direitos autorais © Allerton Press, Inc., 2016