Effect of an oriented crystalline converter on the electromagnetic spectrometer response


如何引用文章

全文:

开放存取 开放存取
受限制的访问 ##reader.subscriptionAccessGranted##
受限制的访问 订阅存取

详细

The results of the experimental studies of the response of an electromagnetic spectrometer with a converter made of 〈111〉 tungsten crystal at electron energies of 26, 28, and 31 GeV are presented. It is found that the ratio of the difference between positions of the cascade curve maximum for misoriented and oriented converter to the difference between energy releases at the cascade curve maximumis a constant value at a given electron energy, converter type and thickness, and is independent of the converter temperature.

作者简介

V. Baskov

Lebedev Physical Institute

编辑信件的主要联系方式.
Email: baskov@x4u.lebedev.ru
俄罗斯联邦, Leninskii pr. 53, Moscow, 119991

补充文件

附件文件
动作
1. JATS XML

版权所有 © Allerton Press, Inc., 2016