Effect of an oriented crystalline converter on the electromagnetic spectrometer response
- Authors: Baskov V.A.1
-
Affiliations:
- Lebedev Physical Institute
- Issue: Vol 43, No 5 (2016)
- Pages: 153-155
- Section: Article
- URL: https://journals.rcsi.science/1068-3356/article/view/227938
- DOI: https://doi.org/10.3103/S1068335616050018
- ID: 227938
Cite item
Abstract
The results of the experimental studies of the response of an electromagnetic spectrometer with a converter made of 〈111〉 tungsten crystal at electron energies of 26, 28, and 31 GeV are presented. It is found that the ratio of the difference between positions of the cascade curve maximum for misoriented and oriented converter to the difference between energy releases at the cascade curve maximumis a constant value at a given electron energy, converter type and thickness, and is independent of the converter temperature.
About the authors
V. A. Baskov
Lebedev Physical Institute
Author for correspondence.
Email: baskov@x4u.lebedev.ru
Russian Federation, Leninskii pr. 53, Moscow, 119991
Supplementary files