Cyclotron 99mTc Production and Quality Control for Medical Applications
- Authors: Al Rayyes A.H.1, Assaad T.1, Ailouti Y.1
-
Affiliations:
- Cyclotron Division, Radioisotopes Department
- Issue: Vol 61, No 1 (2019)
- Pages: 81-85
- Section: Article
- URL: https://journals.rcsi.science/1066-3622/article/view/224928
- DOI: https://doi.org/10.1134/S1066362219010120
- ID: 224928
Cite item
Abstract
A new production method of 99mTc using a high-current solid target was tested. The separation and purification setup was developed to produce high quantity and high specific activity of 99mTcO4− suitable for labeling various ligands for nuclear medicine imaging. A semiautomated target dissolution and separation system has been developed for 99mTcO4− production. The separation is based on a chromatographic column system. The chemical and radiochemical purity was found to be in accordance with the US and European Pharmacopoeia specifications. 99% of activity in the final product belonged to 99mTc. Less than 1% of the 99mTc activity was not incorporated in the target product with MDP kits. Biodistribution data for the labeled MDP kits show that the quality of the produced 99mTc-pertechnetate is identical to that of the pertechnetate from 99Mo/99mTc generators. The application of 99mTc-ethylenedicysteine in human proves the good quality of the produced Na99mTcO4.
About the authors
A. H. Al Rayyes
Cyclotron Division, Radioisotopes Department
Author for correspondence.
Email: cscientific@aec.org.sy
Syrian Arab Republic, Damascus
T. Assaad
Cyclotron Division, Radioisotopes Department
Email: cscientific@aec.org.sy
Syrian Arab Republic, Damascus
Y. Ailouti
Cyclotron Division, Radioisotopes Department
Email: cscientific@aec.org.sy
Syrian Arab Republic, Damascus