Cyclotron 99mTc Production and Quality Control for Medical Applications


如何引用文章

全文:

开放存取 开放存取
受限制的访问 ##reader.subscriptionAccessGranted##
受限制的访问 订阅存取

详细

A new production method of 99mTc using a high-current solid target was tested. The separation and purification setup was developed to produce high quantity and high specific activity of 99mTcO4 suitable for labeling various ligands for nuclear medicine imaging. A semiautomated target dissolution and separation system has been developed for 99mTcO4 production. The separation is based on a chromatographic column system. The chemical and radiochemical purity was found to be in accordance with the US and European Pharmacopoeia specifications. 99% of activity in the final product belonged to 99mTc. Less than 1% of the 99mTc activity was not incorporated in the target product with MDP kits. Biodistribution data for the labeled MDP kits show that the quality of the produced 99mTc-pertechnetate is identical to that of the pertechnetate from 99Mo/99mTc generators. The application of 99mTc-ethylenedicysteine in human proves the good quality of the produced Na99mTcO4.

作者简介

A. Al Rayyes

Cyclotron Division, Radioisotopes Department

编辑信件的主要联系方式.
Email: cscientific@aec.org.sy
阿拉伯叙利亚共和国, Damascus

T. Assaad

Cyclotron Division, Radioisotopes Department

Email: cscientific@aec.org.sy
阿拉伯叙利亚共和国, Damascus

Y. Ailouti

Cyclotron Division, Radioisotopes Department

Email: cscientific@aec.org.sy
阿拉伯叙利亚共和国, Damascus


版权所有 © Pleiades Publishing, Inc., 2019