Configuration of the thermal gap in magnetron-injection guns complying with the hydrodynamic flow model
- Autores: Sapronova T.1, Syrovoi V.1
-
Afiliações:
- All-Russia Electrotechnical Institute
- Edição: Volume 62, Nº 11 (2017)
- Páginas: 1281-1290
- Seção: Electron and Ion Optics
- URL: https://journals.rcsi.science/1064-2269/article/view/198969
- DOI: https://doi.org/10.1134/S106422691710014X
- ID: 198969
Citar
Resumo
An exact solution of the exterior problem for a planar magnetron is constructed in the case of emission limited by the temperature and the space charge. The configuration of the lateral cathode surface and the electrode with a negative potential, which form a profiled thermal gap, is calculated. In contrast to an arbitrary geometry of the electrode in this region, this configuration does not violate the adopted hydrodynamic flow model. The case of a planar diode with the T-mode emission is also studied.