Dynamics of multibubble sonoluminescence intensity
- Authors: Biryukov D.A.1, Gerasimov D.N.2
-
Affiliations:
- Joint Institute for High Temperatures
- National Research University MPEI
- Issue: Vol 43, No 6 (2017)
- Pages: 520-522
- Section: Article
- URL: https://journals.rcsi.science/1063-7850/article/view/204870
- DOI: https://doi.org/10.1134/S1063785017060049
- ID: 204870
Cite item
Abstract
Experimental data indicative of a correlation between the sonoluminescence (SL) intensities at different points of a vessel with a liquid are reported. The SL disappears ~0.1 s after switching off the ultrasonic generator, whereas the liquid conductivity remains the same for several minutes. Thus, the presence of ions in the liquid is not the only cause of the SL.
About the authors
D. A. Biryukov
Joint Institute for High Temperatures
Author for correspondence.
Email: deniger@mail.ru
Russian Federation, Moscow, 125412
D. N. Gerasimov
National Research University MPEI
Email: deniger@mail.ru
Russian Federation, Moscow, 111250