Abstract

Experimental data indicative of a correlation between the sonoluminescence (SL) intensities at different points of a vessel with a liquid are reported. The SL disappears ~0.1 s after switching off the ultrasonic generator, whereas the liquid conductivity remains the same for several minutes. Thus, the presence of ions in the liquid is not the only cause of the SL.

About the authors

D. A. Biryukov

Joint Institute for High Temperatures

Author for correspondence.
Email: deniger@mail.ru
Russian Federation, Moscow, 125412

D. N. Gerasimov

National Research University MPEI

Email: deniger@mail.ru
Russian Federation, Moscow, 111250


Copyright (c) 2017 Pleiades Publishing, Ltd.