Feedback Suppression of the Fast Vertical Oscillations of VEPP-3 SR Beam
- Autores: Fedotov M.G.1,2, Mishnev S.I.1, Ljangasov I.D.1,2
-
Afiliações:
- Budker Institute of Nuclear Physics, Siberian Branch, Russian Academy of Sciences
- Novosibirsk State University
- Edição: Volume 83, Nº 2 (2019)
- Páginas: 116-120
- Seção: Article
- URL: https://journals.rcsi.science/1062-8738/article/view/187233
- DOI: https://doi.org/10.3103/S1062873819020126
- ID: 187233
Citar
Resumo
Experiments are performed on suppressing vertical oscillations of the synchrotron radiation beam of the VEPP-3 storage ring by introducing fast feedback. The detector, based on pin photodiodes with an electronic signal processing path and an electromechanical system of automatic alignment, is a beam position sensor. A pair of iron-free coils is used as a quick corrector. 30 dB suppression of oscillations with a frequency of 50 Hz and 25 dB suppression of powerful interference with a frequency of 690 Hz are obtained in experiments.
Sobre autores
M. Fedotov
Budker Institute of Nuclear Physics, Siberian Branch, Russian Academy of Sciences; Novosibirsk State University
Autor responsável pela correspondência
Email: mihailru@mail.ru
Rússia, Novosibirsk, 630090; Novosibirsk, 630090
S. Mishnev
Budker Institute of Nuclear Physics, Siberian Branch, Russian Academy of Sciences
Email: mihailru@mail.ru
Rússia, Novosibirsk, 630090
I. Ljangasov
Budker Institute of Nuclear Physics, Siberian Branch, Russian Academy of Sciences; Novosibirsk State University
Email: mihailru@mail.ru
Rússia, Novosibirsk, 630090; Novosibirsk, 630090
Arquivos suplementares