Development of method to improve efficiency of residual current device under 1000 V on excavators of mining enterprises


Дәйексөз келтіру

Толық мәтін

Ашық рұқсат Ашық рұқсат
Рұқсат жабық Рұқсат берілді
Рұқсат жабық Тек жазылушылар үшін

Аннотация

This article presents the results of experimental studies on a coal mine. According to the results, the current of single phase-to-earth fault in the network under 1000 V has a value less than the current of the residual current device set point. This article presents a method aimed to improving the efficiency of the residual current device used on excavators and drill-rings at mining enterprises. Indeed, the method developed to improve the efficiency of residual current devices under 1000 V is based on setting up a direct current into three-phase mains with a fixed set-point of protection against any phase-to-ground insulation damage, where electric equipment is switched off due to increases of capacitance between a conductor and earth when live-line bare-hand touching of electric equipment occurs.