Validation of an inductively coupled plasma-optical emission spectrometry method for the determination of major elements in farmed rainbow trout (Oncorhynchus mykiss)


Citar

Texto integral

Acesso aberto Acesso aberto
Acesso é fechado Acesso está concedido
Acesso é fechado Somente assinantes

Resumo

An inductively coupled plasma−optical emission spectrometry method was optimized and validated for the determination of major elements (Ca, K, Mg, Na and P) in cultivated freshwater fish (rainbow trout Oncorhynchus mykiss). The method was validated by analysis of a Certified Reference Material, consisting in a frozen tissue homogenate from lake trout (Salvelinus namaycush namaycush). The linearity of this method was very good, as evidenced by the coefficients of correlation (r) for calibration graphs that were higher than 0.9999 in all cases and by linearity test (response factor <5% and relative calibration graph slope <2%). Accuracy, expressed as relative recovery (%) in comparison with certified concentration ranged from 100 to 109%, and precision, expressed as residual standard deviation (%) ranged from 1.2 to 6.5% (repeatability) and from 1.0 to 9.6% (reproducibility). The limit of quantification ranged from 4 ng/mL (Ca and Mg) to 203 ng/mL (P). The optimized method was applied to major element determination in skin and muscle samples from rainbow trout fillets.

Sobre autores

S. Velasco

Departamento de Producción Animal, Facultad de Veterinaria

Autor responsável pela correspondência
Email: suvelasc@ucm.es
Espanha, Madrid, 28040

L. Ortiz

Departamento de Producción Animal, Facultad de Veterinaria

Email: suvelasc@ucm.es
Espanha, Madrid, 28040

M. Rodríguez

Departamento de Producción Animal, Facultad de Veterinaria

Email: suvelasc@ucm.es
Espanha, Madrid, 28040

A. Rebolé

Departamento de Producción Animal, Facultad de Veterinaria

Email: suvelasc@ucm.es
Espanha, Madrid, 28040

J. Treviño

Departamento de Producción Animal, Facultad de Veterinaria

Email: suvelasc@ucm.es
Espanha, Madrid, 28040

T. Benito

CAI de Técnicas Geológicas

Email: suvelasc@ucm.es
Espanha, Madrid, 28040

I. Gómez-Pinilla

CAI de Técnicas Geológicas

Email: suvelasc@ucm.es
Espanha, Madrid, 28040

S. López-Andrés

CAI de Técnicas Geológicas; Departamento de Cristalografía y Mineralogía, Facultad de Ciencias Geológicas

Email: suvelasc@ucm.es
Espanha, Madrid, 28040; Madrid, 28040


Declaração de direitos autorais © Pleiades Publishing, Ltd., 2017

Este site utiliza cookies

Ao continuar usando nosso site, você concorda com o procedimento de cookies que mantêm o site funcionando normalmente.

Informação sobre cookies