Zinc oxide nanoparticles-based electrochemical sensor for the detection of nitrate ions in water with a low detection limit—a chemometric approach
- Autores: Gumpu M.1,2,3, Nesakumar N.1,2,3, Ramachandra B.1,2,3, Rayappan J.1,2,3
-
Afiliações:
- Nanosensors Lab
- School of Electrical & Electronics Engineering
- Centre for Nanotechnology & Advanced Biomaterials
- Edição: Volume 72, Nº 3 (2017)
- Páginas: 316-326
- Seção: Articles
- URL: https://journals.rcsi.science/1061-9348/article/view/182350
- DOI: https://doi.org/10.1134/S1061934817030078
- ID: 182350
Citar
Resumo
We report for the first time a cyclic voltammetric nitrate sensor with a low detection limit based on the immobilization of zinc oxide nanoparticles on the surface of the platinum working electrode using chitosan membrane. Cyclic voltammetric data demonstrated that zinc oxide nanoparticles can electrochemically reduce nitrate ions to ammonium ions with high conductivity. In order to estimate electroanalytical parameters for each of the nitrate concentrations, Gaussian and Lorentzian curve fitting algorithms were performed on cyclic voltammetric data. Among them, the best analytical performance results were obtained with Gaussian calibration linear model. The zinc oxide modified platinum electrode showed a linear response to nitrate ions over a concentration range from 0.1 to 2.0 mM with a low detection limit and high sensitivity of 10 nM and 39.91 μA/cm2 mM, respectively. The nitrate ion concentrations in drinking water samples were determined using Gaussian calibration linear model and the predicted, added nitrate ion concentration values showed good correlation.
Palavras-chave
Sobre autores
Manju Gumpu
Nanosensors Lab; School of Electrical & Electronics Engineering; Centre for Nanotechnology & Advanced Biomaterials
Email: rjbosco@ece.sastra.edu
Índia, Thanjavur, Tamil Nadu, 613401; Thanjavur, Tamil Nadu, 613401; Thanjavur, Tamil Nadu, 613401
Noel Nesakumar
Nanosensors Lab; School of Electrical & Electronics Engineering; Centre for Nanotechnology & Advanced Biomaterials
Email: rjbosco@ece.sastra.edu
Índia, Thanjavur, Tamil Nadu, 613401; Thanjavur, Tamil Nadu, 613401; Thanjavur, Tamil Nadu, 613401
Bhat Ramachandra
Nanosensors Lab; School of Electrical & Electronics Engineering; Centre for Nanotechnology & Advanced Biomaterials
Email: rjbosco@ece.sastra.edu
Índia, Thanjavur, Tamil Nadu, 613401; Thanjavur, Tamil Nadu, 613401; Thanjavur, Tamil Nadu, 613401
John Rayappan
Nanosensors Lab; School of Electrical & Electronics Engineering; Centre for Nanotechnology & Advanced Biomaterials
Autor responsável pela correspondência
Email: rjbosco@ece.sastra.edu
Índia, Thanjavur, Tamil Nadu, 613401; Thanjavur, Tamil Nadu, 613401; Thanjavur, Tamil Nadu, 613401