Phenoxy-substituted boron subphthalocyanine as a ionophore of ion-selective electrodes


Дәйексөз келтіру

Толық мәтін

Ашық рұқсат Ашық рұқсат
Рұқсат жабық Рұқсат берілді
Рұқсат жабық Тек жазылушылар үшін

Аннотация

Phenoxy-substituted boron subphthalocyanine was synthesized and studied as an ionophore of plasticized polyvinyl chloride membranes of ion-selective electrodes. The electrodes exhibit reversible response to dobutamine, demonstrating the cation function, as well as reversible response to the salicylate anion. The effects of concentration of the ionophore (0.2–5 wt %) and ionic components (sodium tetraphenylborate, TPhBNa, and tributylhexadecylphosphonium bromide, TBGDPBr), including ionic liquids (ILs), such as diphenylbutylethylphosphonium bis(triflyl)imide, diphenylbutylethylphosphonium hexafluorophosphate, and 1,3-dihexadecylimidazolium chloride, as well as plasticizers, such as ortho-nitrophenyloctyl ether and diethyl sebacate, on the electrochemical characteristics of membranes were studied. For the electrode containing 2% of the phenoxy-substituted boron subphthalocyanine in dobutamine and salicylate solutions, the slopes of the electrode function were 36 ± 1 mV/dec and–46 ± 3 mV/dec and the limits of detection (LODs) were 4 × 10–5 M and 3 × 10–4 M, respectively. The addition of an ionic liquid containing the diphenylbutylethylphosphonium cation and the bis(triflyl)imide and hexaflurophosphate anions to the membrane composition had no effect on the response of membrane electrodes to both dobutamine and salicylate. The use of phenoxy-substituted boron subphthalocyanine in an amount of 2% and the TPhBNa additive significantly improved sensor characteristics: the slope of the electrode function (S) for the dobutamine-selective electrode was (54 ± 1) mV/dec and LOD was 1 × 10–5 M. Dobutamine can be determined in the presence of dopamine, adrenalin, and glucose. Electrodes based on 2% phenoxy-substituted boron subphthalocyanine and 0.5% (C16H33)2ImCl, or TBGDPBr in salicylate solutions demonstrate the slope of the electrode function close to the theoretical one and a low limit of detection: S = (–59 ± 1) mV/dec, LOD = 2 × 10–5 M and S = (–57 ± 1) mV/dec, LOD = 4 × 10–5 M, respectively. The anti-Hofmeister selectivity of sensors was observed. The electrode based on phenoxy-substituted boron subphthalocyanine and (C16H33)2ImCl was used for the assay of acetylsalicylic acid in the drug Cardiomagnyl.

Авторлар туралы

N. Shvedene

Department of Chemistry

Хат алмасуға жауапты Автор.
Email: shvedene@gmail.com
Ресей, Moscow, 119991

K. Otkidach

Department of Chemistry

Email: shvedene@gmail.com
Ресей, Moscow, 119991

E. Ondar

Department of Chemistry

Email: shvedene@gmail.com
Ресей, Moscow, 119991

M. Osipova

Department of Chemistry

Email: shvedene@gmail.com
Ресей, Moscow, 119991

T. Dubinina

Department of Chemistry

Email: shvedene@gmail.com
Ресей, Moscow, 119991

L. Tomilova

Department of Chemistry; Institute of Physiologically Active Compounds

Email: shvedene@gmail.com
Ресей, Moscow, 119991; Chernogolovka, Moscow oblast, 142432

I. Pletnev

Department of Chemistry

Email: shvedene@gmail.com
Ресей, Moscow, 119991


© Pleiades Publishing, Ltd., 2017

Осы сайт cookie-файлдарды пайдаланады

Біздің сайтты пайдалануды жалғастыра отырып, сіз сайттың дұрыс жұмыс істеуін қамтамасыз ететін cookie файлдарын өңдеуге келісім бересіз.< / br>< / br>cookie файлдары туралы< / a>